English
Language : 

D60 Datasheet, PDF (1/1 Pages) Total Power International – TOTAL POWER INT. D60 AC-DC 60W POWER SUPPLY WITH DUAL OUTPUT
TOTAL POWER INT.
D60 AC-DC 60W POWER SUPPLY WITH DUAL OUTPUT
.LOW COST, HIGH RELIABILITY
.COMPACT SIZE, LIGHT WEIGHT
.105ºC OUTPUT CAPACITOR
.100% FULL LOAD BURN-IN TEST
.INTERNATIONAL AC INPUT RANGE
.BUILT IN EMI FILTER, LOW RIPPLE NOISE
.HIGH EFFICIENCY, LOW WORKING TEMPERATURE
.SOFT-START CIRCUIT, LIMITING AC SURGE CURRENT
.SHORT CIRCUIT, OVERLOAD, OVER VOLTAGE PROTECTED
SPECIFICATION
MODEL
D-60A
CH1
CH2
D-60B
CH1
CH2
DC OUTPUT VOLTAGE
OUTPUT V. TOLERANCE
OUTPUT RATED CURRENT
OUTPUT CURRENT RANGE
RIPPLE & NOISE
LINE REGULATION
LOAD REGULATION
DC OUTPUT POWER
EFFICIENCY
DC VOLTAGE ADJ.
INPUT VOLTAGE RANGE
AC CURRENT
INRUSH CURRENT
LEAKAGE CURRENT
OVERLOAD PROTECTION
OVER VOLTAGE PROTECTION
OVER TEMP. PROTECTION
TEMP. COEFFICIENT
SETUP, RISE, HOLD UP TIME
VIBRATION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP., HUMIDITY
STORAGE TEMP., HUMIDITY
DIMENSION
WEIGHT
SAFETY STANDARDS
EMC STANDARDS
5V
12V
5V
24V
±2%
±6%
±2%
±5%
4A
3A
3A
1.8A
0.3 -6 A
0.2 -4 A
0.3 -6 A
0.2 -2.2A
75mVp -p
150mVp -p
75mVp -p
150mVp -p
±0.5%
±1%
±0.5%
±0.5%
±0.5%
±4%
±0.5%
±4%
56W
58W
73%
76%
CH1:+10,-5%
CH1:+10,-5%
85~264VAC 47~63Hz; 120~370VDC
2A/115V 1A/230V
COLD START 30A/115V 60A/230V
<1mA/240VAC
105%~150% TYPE:PULSING HICCUP SHUTDOWN RESET:AUTO RECOVERY
CH1:5.75~6.75V
----------
±0.03% / ºC (0~50ºC) ON +5V OUTPUT
800ms, 50ms, 10ms / 115VAC 300ms, 50ms, 80ms / 230VAC
10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms
-10ºC~+60ºC(REFER TO OUTPUT DERATING CURVE), 20%~90% RH
-20ºC~+85ºC, 10%~95% RH
159*97*38mm CASE:901
0.55Kgs
UL1012, TUV EN60950, IEC950, UL1950 APPROVED
CISPR22 (EN55022) CLASS B, IEC801-2,3,4, IEC555-2 VERIFICATION
NOTE : 1.ALL PARAMETERS ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25ºC 70% RH. AMBIENT.
2.TOLERANCE GINCLUDE SET UP TOLERANCE, LINE REGULATION, LOAD REGULATION.
3.RIPPLE & NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF & 47uF CAPACITOR.
4.LINE REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD.
5.LOAD REGULATION IS MEASURED FROM 20% TO 100% RATED LOAD, AND OTHER OUTPUT AT 60% RATED LOAD.
6.EACH OUTPUT PROVIDE UP TO MAXIMUM CURRENT, BUT TOTAL LOAD CAN NOT EXCEED MAX. OUTPUT POWER.
7.C2,3,6 MUST BE REMOVED.
2000-10-03