TC74HCT245AP_07 Datasheet, PDF (4/7 Pages) Toshiba Semiconductor – Octal Bus Transceiver (3-state) | |||
|
◁ |
TC74HCT245AP/AF
AC Characteristics (input: tr = tf = 6 ns)
Characteristics
Output transition time
Symbol
tTLH
tTHL
Propagation delay
tpLH
time
tpHL
Test Condition
CL (pF) VCC (V)
4.5
â¯
50
5.5
4.5
50
5.5
â¯
4.5
150
5.5
Ta = 25°C
Ta = â40 to 85°C
Unit
Min Typ. Max Min Max
â¯
7
12
â¯
15
ns
â¯
6
11
â¯
14
â¯
13
22
â¯
28
â¯
11
20
â¯
25
ns
â¯
18
30
â¯
38
â¯
16
27
â¯
34
3-state output enable
time
tpZL
tpZH
RL = 1 kΩ
4.5
â¯
19
30
â¯
38
50
5.5
â¯
16
27
â¯
34
ns
4.5
â¯
24
38
â¯
48
150
5.5
â¯
22
34
â¯
43
3-state output disable
time
Input capacitance
Output capacitance
Power dissipation
capacitance
tpLZ
tpHZ
RL = 1 kΩ
CIN
DIR, G
CI/O
An, Bn
CPD
(Note)
4.5
â¯
17
30
â¯
38
50
ns
5.5
â¯
16
27
â¯
34
â¯
5
10
â¯
10
pF
â¯
13
â¯
â¯
â¯
pF
â¯
â¯
41
â¯
â¯
â¯
pF
Note:
CPD is defined as the value of the internal equivalent capacitance which is calculated from the operating
current consumption without load.
Average operating current can be obtained by the equation:
ICC (opr) = CPDï½¥VCCï½¥fIN + ICC/8 (per bit)
4
2007-10-01
|
▷ |