English
Language : 

TLP240D Datasheet, PDF (3/18 Pages) Toshiba Semiconductor – Mechanical relay replacements
TLP240D,TLP240DF
8. Absolute Maximum Ratings (Note) (Unless otherwise specified, Ta = 25 )
Characteristics
Symbol Note
Rating
Unit
LED Input forward current
IF
30
mA
Input forward current derating
(Ta ≥ 25 )
∆IF/∆Ta
-0.3
mA/
Input forward current (pulsed)
(100 µs pulse, 100 pps)
IFP
1
A
Input reverse voltage
VR
5
V
Input power dissipation
PD
50
mW
Junction temperature
Tj
125

Detector OFF-state output terminal voltage
VOFF
200
V
ON-state current
ION
250
mA
ON-state current derating
(Ta ≥ 25 )
∆ION/∆Ta
-2.5
mA/
ON-state current (pulsed)
(t = 100 ms, Duty = 1/10)
IONP
750
mA
Output power dissipation
PO
500
mW
Junction temperature
Tj
125

Common Storage temperature
Tstg
-55 to 125

Operating temperature
Topr
-40 to 85

Lead soldering temperature
(10 s)
Tsol
260

Isolation voltage
AC, 60 s, R.H. ≤ 60 %
BVS
(Note 1)
5000
Vrms
Note: Using continuously under heavy loads (e.g. the application of high temperature/current/voltage and the
significant change in temperature, etc.) may cause this product to decrease in the reliability significantly even
if the operating conditions (i.e. operating temperature/current/voltage, etc.) are within the absolute maximum
ratings.
Please design the appropriate reliability upon reviewing the Toshiba Semiconductor Reliability Handbook
("Handling Precautions"/"Derating Concept and Methods") and individual reliability data (i.e. reliability test
report and estimated failure rate, etc).
Note 1: This device is considered as a two-terminal device: Pins 1 and 2 are shorted together, and pins 3 and 4 are
shorted together.
9. Recommended Operating Conditions (Note)
Characteristics
Symbol Note Min Typ. Max Unit
Supply voltage
VDD


160
V
Input forward current
IF
5
7.5
25
mA
ON-state current
ION


250 mA
Operating temperature
Topr
-20

65

Note: The recommended operating conditions are given as a design guide necessary to obtain the intended
performance of the device. Each parameter is an independent value. When creating a system design using
this device, the electrical characteristics specified in this datasheet should also be considered.
©2016 Toshiba Corporation
3
2016-01-06
Rev.3.0