2SK3662_09 Datasheet, PDF (2/6 Pages) Toshiba Semiconductor – Switching Regulator, DC−DC Converter, Motor Drive Applications | |||
|
◁ |
2SK3662
Electrical Characteristics (Ta = 25°C)
Characteristics
Gate leakage current
Drain cut-off current
Drain-source breakdown voltage
Gate threshold voltage
Drain-source ON-resistance
Forward transfer admittance
Input capacitance
Reverse transfer capacitance
Output capacitance
Rise time
Switching time
Turn-on time
Fall time
Turn-off time
Total gate charge
(gate-source plus gate-drain)
Gate-source charge
Gate-drain (âmillerâ) charge
Symbol
Test Condition
Min Typ. Max Unit
IGSS
IDSS
V (BR) DSS
V (BR) DSX
Vth
RDS (ON)
|Yfs|
Ciss
Crss
Coss
VGS = ±16 V, VDS = 0 V
VDS = 60 V, VGS = 0 V
ID = 10 mA, VGS = 0 V
ID = 10 mA, VGS = â20 V
VDS = 10 V, ID = 1 mA
VGS = 4 V, ID = 18 A
VGS = 10 V, ID = 18 A
VDS = 10 V, ID = 18 A
VDS = 10 V, VGS = 0 V, f = 1 MHz
â¯
â¯
±10
μA
â¯
â¯
100
μA
60
â¯
â¯
V
40
â¯
â¯
1.3
â¯
2.5
V
⯠12.5 19
mΩ
â¯
9.4 12.5
28
55
â¯
S
⯠5120 â¯
â¯
300
â¯
pF
â¯
500
â¯
tr
10 V
VGS
ton
0V
ID = 18 A
â¯
6
â¯
VOUT
â¯
19
â¯
ns
tf
â¯
20
â¯
VDD â 30 V
toff
Duty ⤠1%, tw = 10 μs
â¯
115
â¯
Qg
VDD â 48 V, VGS = 10 V,
Qgs
ID = 35 A
Qgd
â¯
91
â¯
â¯
70
â¯
nC
â¯
21
â¯
Source-Drain Diode Ratings and Characteristics (Ta = 25°C)
Characteristics
Continuous drain reverse current
(Note 1)
Pulse drain reverse current
(Note 1)
Forward voltage (diode)
Reverse recovery time
Reverse recovery charge
Symbol
IDR
IDRP
VDSF
trr
Qrr
Test Condition
â¯
â¯
IDR = 35 A, VGS = 0 V
IDR = 35 A, VGS = 0 V,
dIDR/dt = 50 A/μs
Min Typ. Max Unit
â¯
â¯
35
A
â¯
â¯
105
A
â¯
â¯
â1.5
V
â¯
60
â¯
ns
â¯
58
â¯
nC
Marking
K3662
Part No. (or abbreviation code)
Lot No.
Note 4
Note 4: A line under a Lot No. identifies the indication of product
Labels.
Not underlined: [[Pb]]/INCLUDES > MCV
Underlined: [[G]]/RoHS COMPATIBLE or [[G]]/RoHS [[Pb]]
Please contact your TOSHIBA sales representative for details as to
environmental matters such as the RoHS compatibility of Product.
The RoHS is the Directive 2002/95/EC of the European Parliament
and of the Council of 27 January 2003 on the restriction of the use of
certain hazardous substances in electrical and electronic equipment.
2
2009-12-21
|
▷ |