English
Language : 

JDV2S01S Datasheet, PDF (1/2 Pages) Toshiba Semiconductor – TOSHIBA Diode Silicon Epitaxial Planar Type
VCO for UHF band
TOSHIBA Diode Silicon Epitaxial Planar Type
JDV2S01S
• High capacitance ratio: C1V/C4V = 2.0 (typ.)
• Low series resistance: rs = 0.5 Ω (typ.)
• This device is suitable for use in a small-size tuner.
JDV2S01S
Unit in mm
Maximum Ratings (Ta = 25°C)
Characteristics
Reverse voltage
Junction temperature
Storage temperature range
Symbol
VR
Tj
Tstg
Rating
Unit
10
V
150
°C
−55~150
°C
Electrical Characteristics (Ta = 25°C)
JEDEC
EIAJ
TOSHIBA


1-1K1A
Characteristics
Symbol
Test Condition
Reverse voltage
Reverse current
Capacitance
Capacitance ratio
Series resistance
VR
IR
C1V
C4V
C1V/C4V
rs
IR = 1 µA
VR = 10 V
VR = 1 V, f = 1 MHz
VR = 4 V, f = 1 MHz

VR = 1 V, f = 470 MHz
Note: Signal level when capacitance is measured. Vsig = 100 mVrms
Min Typ. Max Unit
10


V


3
nA
2.85 3.15 3.45
pF
1.35 1.57 1.81
1.8
2
2.2


0.5 0.7
Ω
Marking
G
000707EAA2
• TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general
can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the
buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and
to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or
damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the
most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the “Handling
Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability Handbook” etc..
• The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal
equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These TOSHIBA products are
neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or
failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy
control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control
instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this document
shall be made at the customer’s own risk.
2000-12-18 1/2