DF3A6.8FE Datasheet, PDF (1/2 Pages) Toshiba Semiconductor – TOSHIBA Diodes for Protecting Against ESD Epitaxial Planar Type
TOSHIBA Diodes for Protecting Against ESD Epitaxial Planar Type
DF3A6.8FE
Diodes for Protecting Against ESD
DF3A6.8FE
Unit in mm
l Because two devices are mounted on an ultra compact package, it is
possible to allow reducing the number of the parts and the mounting
cost.
l Zener voltage correspond to E24 series.
Maximum Ratings (Ta = 25°C)
Characteristic
Symbol
Rating
Unit
Power dissipation
Junction temperature
Storage temperature range
P
100
mW
Tj
125
°C
Tstg
−55~125
°C
Electrical Characteristics (Ta = 25°C)
JEDEC
EIAJ
TOSHIBA
Weight: 2.3 mg
―
―
1-2SA1A
Characteristic
Zener voltage
Dynamic impedance
Knee dynamic impedance
Reverse current
Symbol
VZ
ZZ
ZZK
IR
Test
Circuit
Test Condition
― IZ = 5mA
― IZ = 5mA
― IZ = 0.5mA
― VR = 5V
Min Typ. Max Unit
6.4
6.8
7.2
V
―
10
―
Ω
―
30
―
Ω
―
―
0.5
µA
Guaranteed Level of Esd Immunity
Marking Equivalent Circuit (Top View)
Test Condition
IEC61000-4-2
(Contact discharge)
ESD Immunity Level
±30kV
000707EAA2
· TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general
can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the
buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and
to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or
damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the
most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the “Handling
Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability Handbook” etc..
· The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal
equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These TOSHIBA products are
neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or
failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy
control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control
instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this document
shall be made at the customer’s own risk.
2001-02-07 1/2