FEATURES
Universal input voltage range
Fixed switching frequency
Short circuit protection
Part Number
TP06AC220S05W
TP06AC220S09W
TP06AC220S12W
TP06AC220S15W
TP06AC220S24W
TP06AC Series
DESCRIPTION: 6W 4KV Isolation Wide Input AC/DC Converters
The rated output power of TP06AC series is 6W with wide input voltage range, for both AC input
and DC input application. High reliability, precision, large power density, ultra-small size, no
external heat sink required, stable output voltage and etc, with over current protection, EMI filter
circuit, the rectifier filter circuit, 4000V isolation voltage, short circuit, overload, internal thermal
protection, Widely used in telecommunications, industrial control, instrument, data acquisition,
signal control and other electronic systems.
Both for AC and DC input voltage
Wide input voltage: 4:1
Overheat protection
RoHS compliant
Over current protection
Operating temperature :-25℃ to 70℃
Input Voltage
Rated
(VAC)
(VDC)
85-300
110-370
85-300
110-370
85-300
110-370
85-300
110-370
85-300
110-370
Output
Voltage(VDC)
Current(A)
5
1.2
9
0.66
12
0.5
15
0.4
24
0.25
Efficiency (Typ. )
%
69
73
75
76
78
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
GENERAL CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Max.
Units
Isolation voltage
Input Frequency
Over current protection
Input / Output 1 minute, leakage current 2mA
10~55Hz
Full input range
4000
VAC
47
63
HZ
Auto recovery
Cooling
Free air convection
Case material
Flame-retardant plastic
INPUT CHARACTERISTICS
Parameter
Startup voltage
Conditions
VAC In module(85V-300V)
Min.
Typ.
Max.
Units
85
220
300
VAC
Startup voltage
VDC In module(110V-370V)
110
220
375
VDC
External fuse recommended value(wiring, rail type Package has included fuse)
Fuse must be connected, recommended 1A / 250V slow-off type
OUTPUT CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Voltage accuracy
Line regulation
Full load
±0.5
Load regulation
10%~100% load
±1
Standby power consumption
Over current protection
≥110%Io, self-recovery
Over voltage protection
Over-voltage shutdown output
Ripple and noise
20MHz bandwidth
50
Short-circuit protection
Hiccup-type, sustainable short-circuit, self-recovery
Switch frequency
140
110VAC
12
Power-down hold time
230VAC
80
Max.
Units
±2
%
%
%
0.3
W
100
mv
Hz
ms
ms
www.gztoppower.con
TEL:0086-20-82019000
Email:sales2@gztoppower.com