English
Language : 

D62LCB Datasheet, PDF (2/3 Pages) TOKO, Inc – Fixed Inductors for Surface Mounting
Fixed Inductors for Surface Mounting
SELECTION GUIDE FOR STANDARD COILS /
TOKO
Inductance (1) Tolerance
Part Number
L (µH)
(%)
A918CY-1R0M
1.0
±20
A918CY-1R5M
1.5
±20
A918CY-2R0M
2.0
±20
A918CY-3R3M
3.3
±20
A918CY-4R7M
4.7
±20
A918CY-6R2M
6.2
±20
A918CY-8R2M
8.2
±20
A918CY-100M
10.0
±20
A918CY-120M
12.0
±20
A918CY-150M
15.0
±20
A918CY-180M
18.0
±20
A918CY-220M
22.0
±20
A918CY-270M
27.0
±20
A918CY-330M
33.0
±20
A918CY-390M
39.0
±20
A918CY-470M
47.0
±20
DC
Resistance (2)
(mΩ) typ.
14
17
24
39
55
62
85
98
128
149
172
211
275
306
394
452
Inductance
Decrease current
(A) max.
3.50
2.94
2.47
1.99
1.59
1.49
1.25
1.22
0.99
0.94
0.83
0.80
0.65
0.63
0.55
0.50
Temperature
Rise current
(A) max.
3.48
2.99
2.33
1.97
1.54
1.45
1.23
1.09
1.10
0.82
0.90
0.74
0.65
0.61
0.56
0.52
(1) Inductance is measured with a LCR meter
(1)
4284A * or equivalent.
(2) DC resistance is measured with a Digital
(2)
Multimeter TR6871 (Advantest) or equivalent.
(3) Maximum allowable DC current is that which
(3)
causes a 10% inductance reduction from the
initial value, or coil temperature to rise by 40°C,
whichever is smaller.
(Reference ambient temperature 20°C)
* Agilent Technologies
*
%
°
°