DG6045C_16 Datasheet, PDF (1/1 Pages) TOKO, Inc – Ferrite Inductors | |||
|
Ferrite Inductors
ãã§ã©ã¤ãã¤ã³ãã¯ã¿
DG6045C
Inductance Range: 1.0~100ïH
Recommended patterns
æ¨å¥¨ãã¿ã¼ã³å³
(Unit: mm)
(Unit: mm)
FEATURES ç¹é·
ï· Low Profile (H=4.5mm Max).
ï· Magnetic Shield.
ï· Ideal for a variety of DC-DC converter inductor
applications.
ï· èå½¢æ§é (é«ã4.5mm Max.)
ï· éç£è·¯æ§é
ï· å種æ©å¨ã®DC-DCã³ã³ãã¼ã¿ç¨ã¤ã³ãã¯ã¿ã«æé©
STANDARD PART NUMBERS æ¨æºåä¸è¦§
TYPE DG6045C (Quantity/reel; 1500 PCS)
åçª
ã¤ã³ãã¯ã¿ã³ã¹(1) 許容差
測å®å¨æ³¢æ°
Part
Number
Inductance(1)
L(ïH)
Tolerance
(%)
Test
Frequency
(KHz)
1255AY-1R0N=P3
1.0
ï±30
100
1255AY-1R2N=P3
1.2
ï±30
100
1255AY-1R8N=P3
1.8
ï±30
100
1255AY-2R2N=P3
2.2
ï±30
100
1255AY-2R7N=P3
2.7
ï±30
100
1255AY-3R3N=P3
3.3
ï±30
100
1255AY-3R9N=P3
3.9
ï±30
100
1255AY-4R7M=P3
4.7
ï±20
100
1255AY-6R8M=P3
6.8
ï±20
100
1255AY-100M=P3
10
ï±20
100
1255AY-150M=P3
15
ï±20
100
1255AY-220M=P3
22
ï±20
100
1255AY-270M=P3
27
ï±20
100
1255AY-330M=P3
33
ï±20
100
1255AY-470M=P3
47
ï±20
100
1255AY-680M=P3
68
ï±20
100
1255AY-101M=P3
100
ï± 20
100
ç´æµæµæ(2)
DC
Resistance(2)
(mï)Max. (Typ.)
12.0 (10)
14.4 (12)
16.8 (14)
19.2 (16)
21.6 (18)
25.2 (21)
26.4 (22)
27.6 (23)
43.2 (36)
56.4 (47)
75.6 (63)
117.6 (98)
162.0 (135)
174.0 (145)
252.0 (210)
372.0 (310)
552.0 (460)
ç´æµéç³è¨±å®¹é»æµ(3) 温度ä¸æ許容é»æµ(4)
Inductance
DecreaseCurrent(3)
(A) Max. (Typ.)
ï L =30%
L
Temperature
Rise Current(4)
ïT=40ï°C
(A) Max. (Typ.)
9.5(13)
8.4 (11)
6.8 (9.1)
6.3 (8.4)
5.6 (7.5)
5.2 (6.9)
4.7 (6.3)
4.5 (6.0)
3.6 (4.8)
3.1 (4.1)
2.5 (3.3)
2.0 (2.7)
1.8 (2.4)
1.7 (2.2)
1.4 (1.9)
1.2 (1.6)
0.9 (1.2)
6.5(8.1)
5.9 (7.4)
5.3 (6.6)
4.7 (5.9)
4.6 (5.7)
4.4 (5.5)
4.2 (5.2)
4.0 (4.7)
3.4 (4.2)
2.9 (3.6)
2.4 (3.0)
1.9 (2.4)
1.8 (2.1)
1.5 (1.9)
1.3 (1.6)
1.0 (1.3)
0.9 (1.1)
(1) Inductance is measured with a LCR meter 4284A (Agilent
Technologies) or equivalent.
Test frequency at 100kHz
(2) DC resistance is measured with 34420A (Agilent Technologies) or
3541(HIOKI). (Reference ambient temperature 25°C)
(3) Inductance Decrease Current based upon 30% inductance
reduction from the initial value
(4) Temperature Rise Current based upon 40°C temperature rise.
(Reference ambient temperature 20°C)
(1) ã¤ã³ãã¯ã¿ã³ã¹ã¯LCRã¡ã¼ã¿4284Aï¼Agilent Technologiesï¼
ã¾ãã¯åçåã«ãã測å®ããã
測å®å¨æ³¢æ°ã¯100kHzã
(2) ç´æµæµæã¯æ¸¬å®å¨34420Aï¼Agilent Technologiesï¼ã¾ãã¯3541
ï¼HIOKIï¼ã¨åçåã«ãã測å®ãããï¼å¨å²æ¸©åº¦25°Cï¼
(3) ç´æµéç³è¨±å®¹é»æµï¼ç´æµéç³é»æµãæµããæã¤ã³ãã¯ã¿ã³ã¹ã®å¤
ãåæå¤ãã30%æ¸å°ããç´æµé»æµå¤
(4) 温度ä¸æ許容é»æµï¼ã³ã¤ã«ã®æ¸©åº¦ã40°Cä¸æããå¤
ï¼å¨å²æ¸©åº¦20°Cãåºæºã¨ãããï¼
|