D52LC_16 Datasheet, PDF (1/1 Pages) TOKO, Inc – Ferrite Inductors | |||
|
Ferrite Inductors
ãã§ã©ã¤ãã¤ã³ãã¯ã¿
D52LC
Inductance Range: 1.2~100ïH
Recommended patterns
æ¨å¥¨ãã¿ã¼ã³å³
(Unit: mm)
FEATURES ç¹é·
ï· Low profile (5.2mm Max. square, 2.0mm Max. height).
ï· Magnetically shielded construction and low DC resistance.
ï· Suitable for large currents.
ï· Ideal for a variety of DC-DC converter inductor applications.
ï· å°åèå½¢æ§é ï¼5.2mmè§Max.ãé«ã2.0 mm Max.ï¼
ï· éç£è·¯æ§é ãä½ç´æµæµæ
ï· å¤§é»æµå¯¾å¿
ï· å種æ©å¨ã®DC-DCã³ã³ãã¼ã¿ç¨ã¤ã³ãã¯ã¿ã«æé©
STANDARD PART NUMBERS æ¨æºåä¸è¦§
TYPE D52LC (Quantity/reel; 2,000 PCS)
åçª
ã¤ã³ãã¯ã¿ã³ã¹(1)
許容差
ç´æµæµæ(2)
Part
Number
Inductance(1)
(ïH)
Tolerance
(%)
DC
Resistance(2)
(mï) Max. (Typ.)
#A914BYW-1R2M=P3
1.2
#A914BYW-2R2M=P3
2.2
#A914BYW-3R5M=P3
3.5
#A914BYW-4R7M=P3
4.7
#A914BYW-6R8M=P3
6.8
#A914BYW-100M=P3
10
#A914BYW-150M=P3
15
#A914BYW-220M=P3
22
#A914BYW-330M=P3
33
#A914BYW-470M=P3
47
#A914BYW-680M=P3
68
#A914BY-101M=P3
100
ï± 20
ï± 20
ï± 20
ï± 20
ï± 20
ï± 20
ï± 20
ï± 20
ï± 20
ï± 20
ï± 20
ï± 20ï
44 (37)
59 (49)
73 (61)
87 (72)
105 (84)
150 (125)
210 (175)
275 (230)
455 (375)
730 (605)
935 (780)
1500 (1250)
ç´æµéç³è¨±å®¹é»æµ(3)
Inductance
Decrease Current(3)
(A) Max. (Typ.)
ïL
L
=10%
ïL
L
=30%
1.94 (2.59)
2.15 (2.88)
1.44 (1.93)
1.63 (2.18)
1.19 (1.59)
1.34 (1.80)
1.01 (1.35)
1.14 (1.52)
0.83 (1.11)
0.95 (1.27)
0.67 (0.90)
0.56 (0.76)
0.49 (0.66)
0.39 (0.53)
0.32 (0.43)
0.76 (1.03)
0.63 (0.85)
0.56 (0.75)
0.44 (0.59)
0.36 (0.49)
0.26 (0.35)
0.20 (0.28)
0.30 (0.41)
0.23 (0.32)
温度ä¸æ許容é»æµ(3)
Temperature
Rise Current(3)
ïT=40ï°C
(A) Max. (Typ.)
2.44 (2.87)
1.74 (2.06)
1.54 (1.82)
1.30 (1.54)
1.17 (1.38)
0.93 (1.10)
0.77 (0.91)
0.70 (0.83)
0.51 (0.61)
0.38 (0.45)
0.35 (0.42)
0.26 (0.31)
(1) Inductance is measured with a LCR meter 4284A (Agilent
Technologies) or equivalent.
Test frequency at 100kHz
(2) DC resistance is measured with 34420A (Agilent Technologies) or
3541(HIOKI). (Reference ambient temperature 25°C)
(3) Maximum allowable DC current is that which causes a 30%
inductance reduction from the initial value, or coil temperature to
rise by 40°C, whichever is smaller. (Reference ambient
temperature 20°C)
(1) ã¤ã³ãã¯ã¿ã³ã¹ã¯LCRã¡ã¼ã¿4284Aï¼Agilent Technologiesï¼
ã¾ãã¯åçåã«ãã測å®ããã
測å®å¨æ³¢æ°ã¯100kHzã
(2) ç´æµæµæã¯æ¸¬å®å¨34420Aï¼Agilent Technologiesï¼ã¾ãã¯3541
ï¼HIOKIï¼ã¨åçåã«ãã測å®ãããï¼å¨å²æ¸©åº¦25°Cï¼
(3) æ大許容é»æµã¯ãç´æµéç³é»æµãæµããæã¤ã³ãã¯ã¿ã³ã¹ã®å¤ã
åæå¤ãã30ï¼
æ¸å°ããç´æµé»æµå¤ãã¾ãã¯ç´æµé»æµã«ããã
ã³ã¤ã«ã®æ¸©åº¦ã40°Cä¸æã®ä½ããå°ããå¤ãï¼å¨å²æ¸©åº¦20°Cã
åºæºã¨ãããï¼
|