D518LC
Inductance Range: 1.2~47µH
DIMENSIONSʗੇܗ֎๏ਤ
˘5.2 Max.
1.8 Max.
0.15
0.6
4.2
Recommended patterns
ਪ঑ύλʔϯਤ
ํ޲දࣔ
Direction indication
FEATURESʗಛɹ௕
• Low profile (5.2mm Max. square, 1.8 mm Max. height).
• Magnetically shielded construction and low DC resistance.
• Suitable for large currents.
• ideal for a variety of DC-DC converter inductor
applications.
• Most suitable for portable electronic equipments requining
low profile and high density mounting.
• RoHS compliant.
1.4
(Unit: mm)
4.0
6.0
(Unit: mm)
• খܕബߏܗ଄ʢNN֯ .BYɺߴ͞NN.BYʣ
• ด࣓࿏ߏ଄ɺ௿௚ྲྀ఍߅
• େిྲྀରԠ
• ֤छثػͷ%$%$ίϯόʔλ༻ΠϯμΫλʹ࠷ద
• ֤छܞଳثػࢠిܕͷബܗԽɺߴີ౓࣮૷΁ͷରԠʹ࠷దͰ͢ɻ
• 3P)4ࢦྩରԠ
SELECTION GUIDE FOR STANDARD COILS
TYPE D518LC (Quantity/reel; 2,000 PCS)
౦ޫ඼൪
ΠϯμΫλϯε 
ڐ༰ࠩ
TOKO
Part
Number
Inductance (1)
(µH)
Tolerance
(%)
#A960AW-1R2M
1.2
± 20
#A960AW-1R8M
1.8
± 20
#A960AW-2R3M
2.3
± 20
#A960AW-3R6M
3.6
± 20
#A960AW-4R3M
4.3
± 20
#A960AW-5R1M
5.1
± 20
#A960AW-6R8M
6.8
± 20
#A960AW-100M
10.0
± 20
#A960AW-150M
15.0
± 20
#A960AW-180M
18.0
± 20
#A960AW-220M
22.0
± 20
#A960AW-330M
33.0
± 20
#A960AW-470M
47.0
± 20
௚ྲྀ఍߅ 
௚ྲྀॏ৞ڐ༰ిྲྀ 
Թ౓্ঢڐ༰ిྲྀ 
DC
Inductance Decrease Current(3) Temperature
Resistance (2)
(A) Max. (Typ.)
Rise Current(3)
(mΩ) Max.
(Typ.)
∆L
L
=10%
∆L
L
=30%
∆ T=40°C
(A) Max. (Typ.)
46 (38)
54 (45)
63 (53)
82 (68)
92 (77)
105 (86)
130 (105)
180 (150)
270 (225)
320 (265)
450 (375)
640 (530)
930 (780)
1.60 (2.15)
1.40 (1.94)
1.20 (1.66)
1.00 (1.35)
0.92 (1.23)
0.82 (1.10)
0.72 (0.97)
0.60 (0.81)
0.48 (0.65)
0.44 (0.59)
0.38 (0.52)
0.31 (0.42)
0.25 (0.34)
2.00 (2.78)
1.80 (2.48)
1.50 (2.13)
1.20 (1.73)
1.10 (1.55)
1.00 (1.43)
0.94 (1.26)
0.80 (1.07)
0.64 (0.86)
0.56 (0.76)
0.49 (0.66)
0.41 (0.55)
0.33 (0.45)
1.97 (2.32)
1.77 (2.08)
1.67 (1.96)
1.42 (1.68)
1.34 (1.58)
1.18 (1.39)
1.14 (1.34)
0.95 (1.12)
0.77 (0.90)
0.70 (0.83)
0.62 (0.73)
0.49 (0.58)
0.39 (0.46)
(1) Inductance is measured with a LCR meter 4284A (Agilent
Technologies) or equivalent.
Test frequency at 100kHz
(2) DC resistance is measured with a Digital Multimeter TR6871
(Advantest) or equivalent.
(3) Maximum allowable DC current is that which causes a 30%
inductance reduction from the initial value, or coil temperature to
rise by 40°C, whichever is smaller. (Reference ambient temperature
20°C)
 ΠϯμΫλϯε͸-$3ϝʔλ"ʢ"HJMFOU 5FDIOPMPHJFTʣ·ͨ͸
ಉ౳඼ʹΑΓଌఆ͢Δɻ
ଌఆप೾਺͸L)[Ͱ͢ɻ
 ௚ྲྀ఍߅͸σδλϧϚϧνϝʔλ53ʢ"EWBOUFTUʣ·ͨ͸ಉ౳
඼ʹΑΓଌఆ͢Δɻ
 ࠷େڐ༰ిྲྀ͸ɺ௚ྲྀॏ৞ిྲྀΛྲྀͨ࣌͠ΠϯμΫλϯεͷ஋͕ॳ
ظ஋ΑΓˋݮগ͢Δ௚ྲྀిྲྀ஋ɺ·ͨ͸௚ྲྀిྲྀʹΑΓɺίΠϧ
ͷԹ౓͕ˆ্ঢͷԿΕ͔খ͍͞஋Ͱ͢ɻʢपғԹ౓ˆΛج४ͱ͢
Δɻʣ