English
Language : 

D312F Datasheet, PDF (1/1 Pages) TOKO, Inc – Fixed Inductors for Cellular Phone
Fixed Inductors for Cellular Phone
͚ͮ
ܞଳి࿩༻ ໘࣮૷ ݻఆΠϯμΫλ
D312F
Inductance Range: 1.0~47µH
DIMENSIONSʗੇܗ֎๏ਤ
3.8 Max.
1.2 Max.
1.0
Recommended patterns
ਪ঑ύλʔϯਤ
3.6
1.4
(Unit: mm)
Resist Zone
(Unit: mm)
FEATURESʗಛɹ௕
• Low profile (3.8mm Max. square, 1.2mm Max. height)
• Clears free-fall drop tests in which it is dropped onto a
concrete floor from a height of 1.5 m, thus meeting
requirements specified for use in cellular phones.
• Features an open magnetic circuit, but its thin dimensions
result in minimum leakage flux and result in minimum
electromagnetic interference generated.
• RoHS compliant.
• খܕബߏܗ଄ʢmm֯.BYɺߴ͞mm .ax.ʣ
ܞ •ଳి࿩ʹཁ͞ٻΕΔ ϝʔτϧ͔ΒίϯΫϦʔτচ΁
ͷࣗ༝མԼিܸࢼݧΛΫϦΞ
• ։࣓࿏͕ͩް͕͞ඇৗʹബ͍ͨΊɺ࿙Ε࣓ଋ͕গͳ͘֎
෦΁ͷӨ͕ڹগͳ͍
• 3P)4ࢦྩରԠ
SELECTION GUIDE FOR STANDARD COILS
TYPE D312F (Quantity/reel; 2,000 PCS)
౦ޫ඼൪
ΠϯμΫλϯε 
ڐ༰ࠩ
TOKO
Part
Number
Inductance (1)
(µH)
Tolerance
(%)
௚ྲྀ఍߅ 
௚ྲྀॏ৞ڐ༰ిྲྀ 
Թ౓্ঢڐ༰ిྲྀ 
DC
Resistance (2)
(Ω) Max. (Typ.)
Inductance Decrease Current(3)
(A) Max. (Typ.)
∆L
L
=10%
∆L
L
=30%
Temperature
Rise Current(3)
∆ T=40°C
(A) Max. (Typ.)
976AS-1R0N
976AS-1R5M
976AS-2R2M
976AS-3R3M
976AS-4R7M
1.0
±30
0.12 (0.10)
1.48 (1.97)
1.76 (2.35)
1.15 (1.36)
1.5
±20
0.14 (0.12)
1.31 (1.74)
1.56 (2.08)
1.13 (1.33)
2.2
±20
0.17 (0.14)
1.08 (1.44)
1.20 (1.60)
0.95 (1.12)
3.3
±20
0.26 (0.22)
0.92 (1.22)
1.00 (1.34)
0.72 (0.84)
4.7
±20
0.38 (0.32)
0.74 (0.98)
0.83 (1.10)
0.71 (0.83)
976AS-6R8M
6.8
±20
0.48 (0.40)
0.63 (0.84)
0.71 (0.95)
0.51 (0.60)
976AS-8R2M
8.2
±20
0.56 (0.46)
0.58 (0.78)
0.67 (0.89)
0.47 (0.55)
976AS-100M
10.0
±20
0.79 (0.66)
0.50 (0.66)
0.56 (0.74)
0.49 (0.57)
976AS-120M
12.0
±20
0.90 (0.75)
0.46 (0.62)
0.53 (0.70)
0.38 (0.45)
976AS-150M
15.0
±20
1.01 (0.84)
0.43 (0.57)
0.49 (0.65)
0.46 (0.54)
976AS-220M
22.0
±20
1.46 (1.22)
0.35 (0.46)
0.41 (0.54)
0.36 (0.43)
976AS-270M
27.0
±20
1.98 (1.65)
0.32 (0.42)
0.38 (0.50)
0.31 (0.37)
976AS-330M
33.0
±20
2.26 (1.88)
0.29 (0.39)
0.33 (0.44)
0.30 (0.36)
976AS-470M
47.0
±20
3.28 (2.74)
0.23 (0.31)
0.28 (0.37)
0.21 (0.24)
(1) Inductance is measured with a LCR meter 4284A* or equivalent.
Test frequency at 100KHz
(2) DC resistance is measured with a Digital Multimeter TR6871
(Advantest) or equivalent.
(3) Maximum allowable DC current is that which causes a 30%
inductance reduction from the initial value, or coil temperature to rise
by 40°C, whichever is smaller.
(Reference ambient temperature 20°C)
* Agilent Technologies
 ΠϯμΫλϯε͸-$3ϝʔλ" ·ͨ͸ಉ౳඼ʹΑΓଌఆ͢Δɻ
ଌఆप೾਺͸,)[Ͱ͢ɻ
 ௚ྲྀ఍߅͸σδλϧϚϧνϝʔλ53 "EWBOUFTU ·ͨ͸ಉ౳඼
ʹΑΓଌఆ͢Δɻ
 ࠷େڐ༰ిྲྀ͸ɺ௚ྲྀॏ৞ిྲྀΛྲྀͨ࣌͠ΠϯμΫλϯεͷ஋͕ॳ
ظ஋ΑΓݮগ͢Δ௚ྲྀిྲྀ஋ɺ·ͨ͸௚ྲྀిྲྀʹΑΓɺίΠϧ
ͷԹ౓͕ˆ্ঢͷԿΕ͔খ͍͞஋Ͱ͢ɻ
ʢपғԹ౓ˆΛج४ͱ͢Δɻʣ
* Agilent Technologies