English
Language : 

C2X Datasheet, PDF (1/1 Pages) TOKO, Inc – Radial Type Fixed Inductors
Radial Type Fixed Inductors ϥδΞϧλΠϓݻఆΠϯμΫλ
C2X
Inductance Range: 10~1000μH
DIMENSIONSʗ֎ੇܗ๏ਤ
FEATURESʗಛ௕
П10.5 Max.
14.5 Max. 5.0

П0.7
(Unit: mm)
• Ideal as a choke coil for noise filtering and
DC-DC Convertor application.
• RoHS compliant.
• ϊΠζϑΟϧλ΍DC-DCίϯόʔλ༻Π
ϯμΫλʹ࠷ద
• RoHSࢦྩରԠ
TYPE C2X
౦ޫ඼൪
TOKO
Part
Number
#C2X-A100K
#C2X-A120K
#C2X-A150K
#C2X-A180K
#C2X-A220K
#C2X-A270K
#C2X-A330K
#C2X-A390K
#C2X-A470K
#C2X-A560K
#C2X-A680K
#C2X-A820K
#C2X-A101K
#C2X-A121K
#C2X-A151K
#C2X-A181K
#C2X-A221K
#C2X-A271K
#C2X-A331K
#C2X-A391K
#C2X-A471K
#C2X-A561K
#C2X-A681K
#C2X-A821K
#C2X-A102K
SELECTION GUIDE FOR STANDARD COILS
ΠϯμΫλϯε(1)
Inductance(1)
(μH)
10
12
15
18
22
27
33
39
47
56
68
82
100
120
150
180
220
270
330
390
470
560
680
820
1000
ڐ༰ࠩ
Tolerance
(%)
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
௚ྲྀ఍߅(3)
DC
Resistance(3)
(mΩ) Max.
28
30
34
37
41
54
60
67
74
83
94
110
140
150
210
230
290
320
410
460
580
720
810
970
1100
࠷େڐ༰ిྲྀ(2)
Rated
DC Current(2)
(A) Max.
4.5
4.2
4.1
3.8
3.6
3.2
3.1
3.0
2.9
2.8
2.7
2.4
2.1
2.0
1.7
1.6
1.4
1.3
1.2
1.1
0.88
0.78
0.83
0.75
0.67
(1) Inductance is measured with a LCR meter 4284A (Agilent
Technologies) or equivalent.
Test frequency at 1.0kHz.
(2) Rated DC current is that which causes a 10% inductance
reduction from the initial value, or coil temperature to rise by
40°C, whichever is smaller. (Reference ambient temperature
25°C)
(3) DC resistance is measured with a digital multimeter TR6871
(Advantest) or equivalent.
(1) ΠϯμΫλϯε͸LCRϝʔλ4284A(Agilent Technologies)·ͨ͸
ಉ౳඼ʹΑΓଌఆ͢Δɻ
ଌఆप೾਺͸1.0kHzͰ͢ɻ
(2) ࠷େڐ༰ిྲྀ͸ɺ௚ྲྀॏ৞ిྲྀΛྲྀͨ࣌͠ΠϯμΫλϯεͷ஋͕
ظॳ஋ΑΓ10ݮˋগ͢Δ௚ྲྀిྲྀ஋ɺ·ͨ͸௚ྲྀిྲྀʹΑΓɺί
ΠϧͷԹ౓͕40ˆ্ঢͷԿΕ͔খ͍͞஋Ͱ͢ɻ(पғԹ౓25ˆΛ
ج४ͱ͢Δɻ)
(3) ௚ྲྀ఍߅͸σδλϧϚϧνϝʔλTR6871(Advantest)·ͨ͸ಉ౳
඼ʹΑΓଌఆ͢Δɻ
ç