English
Language : 

LM3S828_16 Datasheet, PDF (93/531 Pages) Texas Instruments – Stellaris LM3S828 Microcontroller
Stellaris® LM3S828 Microcontroller
Bit/Field
1
0
Name
INTEN
ENABLE
Type
R/W
R/W
Reset
0
Description
Interrupt Enable
Value
0
1
Description
Interrupt generation is disabled. Software can use the
COUNT bit to determine if the counter has ever reached 0.
An interrupt is generated to the NVIC when SysTick counts
to 0.
0
Enable
Value
0
1
Description
The counter is disabled.
Enables SysTick to operate in a multi-shot way. That is, the
counter loads the RELOAD value and begins counting down.
On reaching 0, the COUNT bit is set and an interrupt is
generated if enabled by INTEN. The counter then loads the
RELOAD value again and begins counting.
July 14, 2014
93