English
Language : 

TM4C123BH6ZRB Datasheet, PDF (900/1337 Pages) Texas Instruments – Tiva TM4C123BH6ZRB Microcontroller
Analog-to-Digital Converter (ADC)
Bit/Field
5
4
3
2
Name
DCINT5
DCINT4
DCINT3
DCINT2
Type
WO
WO
WO
WO
Reset
0
0
0
0
Description
Digital Comparator Interrupt 5
Value Description
0 No effect.
1 Resets the Digital Comparator 5 interrupt unit to its initial
conditions.
When the interrupt has been cleared, this bit is automatically cleared.
Because the digital comparators use the current and previous ADC
conversion values to determine when to assert the interrupt, it is
important to reset the digital comparator to initial conditions when starting
a new sequence so that stale data is not used.
Digital Comparator Interrupt 4
Value Description
0 No effect.
1 Resets the Digital Comparator 4 interrupt unit to its initial
conditions.
When the interrupt has been cleared, this bit is automatically cleared.
Because the digital comparators use the current and previous ADC
conversion values to determine when to assert the interrupt, it is
important to reset the digital comparator to initial conditions when starting
a new sequence so that stale data is not used.
Digital Comparator Interrupt 3
Value Description
0 No effect.
1 Resets the Digital Comparator 3 interrupt unit to its initial
conditions.
When the interrupt has been cleared, this bit is automatically cleared.
Because the digital comparators use the current and previous ADC
conversion values to determine when to assert the interrupt, it is
important to reset the digital comparator to initial conditions when starting
a new sequence so that stale data is not used.
Digital Comparator Interrupt 2
Value Description
0 No effect.
1 Resets the Digital Comparator 2 interrupt unit to its initial
conditions.
When the interrupt has been cleared, this bit is automatically cleared.
Because the digital comparators use the current and previous ADC
conversion values to determine when to assert the interrupt, it is
important to reset the digital comparator to initial conditions when starting
a new sequence so that stale data is not used.
900
June 12, 2014
Texas Instruments-Production Data