electrical characteristics over recommended operating free-air temperature range
PARAMETER
TEST CONDITIONS
MIN TYP† MAX UNIT
VIK
VOH
VOL
IOZH
IOZL
II
IIH
IIL
CLK
All others
VCC = 4.5 V,
VCC = 4.5 V,
VCC = 4.5 V,
VCC = 5.5 V,
VCC = 5.5 V,
VCC = 5.5 V,
VCC = 5.5 V,
VCC = 5.5 V,
II = − 18 mA
IOH = − 2 mA
IOL = 12 mA
VO = 2.7 V
VO = 0.4 V
VI = 5.5 V
VI = 2.7 V
VI = 0.4 V
−1.2 V
2.4 3.5
V
0.25 0.5 V
0.1 mA
−0.1 mA
1 mA
25 μA
− 0.2
mA
− 0.1
IOS‡
VCC = 5.5 V,
VO = 0.5 V
− 30
−90 mA
ICC
VCC = 5.5 V,
VI = GND,
Outputs open
200 mA
Ci
f = 1 MHz,
VI = 2 V
5.5
pF
Co
f = 1 MHz,
VO = 2 V
8
pF
Cclk
f = 1 MHz,
VCLK = 2 V
7
pF
† All typical values are at VCC = 5 V, TA = 25°C.
‡ Not more than one output should be shorted at a time, and the duration of the short circuit should not exceed one second. VO is set at 0.5 V to
avoid test problems caused by test equipment ground degradation.
switching characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
TEST CONDITION
MIN
MAX
fmax§
tpd
tpd
tpd
ten
tdis
External feedback
I, I/O
I/O
I, I/O (reset)
Q
CLK
Q
I, I/O
I/O, Q
I, I/O
I/O, Q
R1 = 390 Ω,
R2 = 750 Ω,
See Figure 4
33.3
20
25
15
20
20
§ fmax (with feedback) = tsu
)
1
tpd(CLK
to
Q).Verification
of
tsu
and
tpd(CLK
to
Q)
may
be
used
to
verify
expected
performance.
UNIT
MHz
ns
ns
ns
ns
ns