CDCLVP1208 Datasheet, PDF (8/22 Pages) Texas Instruments – Eight LVPECL Output, High-Performance Clock 2:8 Buffer | |||
|
◁ |
CDCLVP1208
SCAS890B â OCTOBER 2009 â REVISED AUGUST 2011
www.ti.com
TEST CONFIGURATIONS
This section describes the function of each block for the CDCLVP1208. Figure 3 through Figure 9 illustrate how
the device should be setup for a variety of test configurations.
VIH
IN
Vth
VIL
IN
Vth
Figure 3. DC-Coupled LVCMOS Input During Device Test
VCC
Vthmax
VIHmax
VILmax
VIH
Vth
Vth
VIL
VIHmin
Vthmin
GND
VILmin
Figure 4. Vth Variation over LVCMOS Levels
VCC
130 W
VCC
130 W
LVPECL
CDCLVP1208
82 W
82 W
Figure 5. DC-Coupled LVPECL Input During Device Test