TLC27M2ACDRG4 Datasheet, PDF (7/50 Pages) Texas Instruments – LinCMOS PRECISION DUAL OPERATIONAL AMPLIFIERS | |||
|
◁ |
TLC27M2, TLC27M2A, TLC27M2B, TLC27M7
LinCMOS PRECISION DUAL OPERATIONAL AMPLIFIERS
SLOS051E â OCTOBER 1987 â REVISED AUGUST 2008
electrical characteristics at specified free-air temperature, VDD = 5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TLC27M2I
TLC27M2AI
TAâ
TLC27M2BI
UNIT
TLC27M7I
MIN TYP MAX
VIO
Input offset voltage
TLC27M2I
TLC27M2AI
TLC27M2BI
TLC27M7I
VO = 1.4 V,
RS = 50 â¦,
VO = 1.4 V,
RS = 50 â¦,
VO = 1.4 V,
RS = 50 â¦,
VO = 1.4 V,
RS = 50 â¦,
VIC = 0,
RL = 100 kâ¦
VIC = 0,
RL = 100 kâ¦
VIC = 0,
RL = 100 kâ¦
VIC = 0,
RL = 100 kâ¦
25°C
Full range
25°C
Full range
25°C
Full range
25°C
Full range
1.1
10
13
mV
0.9
5
7
220 2000
3500
µV
185 500
2000
αVIO
Average temperature coefficient of input
offset voltage
25°C to
85°C
1.7
µV/°C
IIO
Input offset current (see Note 4)
VO = 2.5 V,
VIC = 2.5 V
25°C
85°C
0.1
60
pA
24 1000
IIB
Input bias current (see Note 4)
VO = 2.5 V,
VIC = 2.5 V
25°C
85°C
0.6
60
pA
200 2000
VICR
Common-mode input voltage range
(see Note 5)
â0.2 â0.3
25°C
to
to
V
4 4.2
â 0.2
Full range
to
V
3.5
25°C
3.2 3.9
VOH High-level output voltage
VID = 100 mV,
RL = 100 kâ¦
â 40°C
3 3.9
V
85°C
3
4
25°C
0
50
VOL
Low-level output voltage
VID = â100 mV,
IOL = 0
â 40°C
85°C
0
50 mV
0
50
Large-signal differential voltage
AVD
amplification
VO = 0.25 V to 2 V, RL = 100 kâ¦
25°C
â 40°C
85°C
25 170
15 270
15 130
V/mV
25°C
65
91
CMRR Common-mode rejection ratio
VIC = VICRmin
â 40°C
60
90
dB
85°C
60
90
kSVR
Supply-voltage rejection ratio
(âVDD /âVIO)
25°C
70
93
VDD = 5 V to 10 V, VO = 1.4 V
â 40°C
60
91
dB
85°C
60
94
IDD
Supply current (two amplifiers)
VO = 2.5 V,
No load
VIC = 2.5 V,
25°C
â 40°C
85°C
210 560
315 800 µA
160 400
â Full range is â 40°C to 85°C.
NOTES: 4. The typical values of input bias current and input offset current below 5 pA were determined mathematically.
5. This range also applies to each input individually.
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265
7
|
▷ |