English
Language : 

74AC11652_11 Datasheet, PDF (7/11 Pages) Texas Instruments – OCTAL BUS TRANSCEIVER AND REGISTERS WITH 3-STATE OUTPUTS
74AC11652
OCTAL BUS TRANSCEIVER AND REGISTERS
WITH 3-STATE OUTPUTS
SCAS088A - DECEMBER 1989 - REVISED APRIL 1996
switching characteristics over recommended operating free-air temperature range,
VCC = 5 V ± 0.5 V (unless otherwise noted) (see Figure 2)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
TA = 25°C
MIN
MIN TYP MAX
fmax
tPLH
tPHL
tPLH
tPHL
tPLH
tPHL
tPLH
tPHL
tPZH
tPZL
tPHZ
tPLZ
tPZH
tPZL
tPHZ
tPLZ
A or B
CLKBA or CLKAB
SBA or SAB
(A or B high)
SBA or SAB
(A or B low)
OEBA
OEBA
OEAB
OEAB
B or A
A or B
A or B
A or B
A
A
B
B
105
105
2.4 5.2 7.6 2.4
3.1
6 8.7 3.1
3.6 6.7 9.5 3.6
4.4 7.8 10.8 4.4
2.9 5.6 8.1 2.9
3.8 6.9 9.6 3.8
3.3 6.2 8.8 3.3
4 7.1 9.9
4
3.3 6.6 9.6 3.3
4.2 7.4 10.9 4.2
3.6 5.5 7.2 3.6
3.3
5 6.7 3.3
4.1 7.2 10.1 4.1
4.6 7.9 11.1 4.6
3.9 5.6 7.3 3.9
3.4 5.2 6.8 3.4
MAX
8.6
9.6
10.7
12
9.1
10.7
9.9
10.9
10.9
12.2
7.6
7.1
11.3
12.3
7.6
7.2
UNIT
MHz
ns
ns
ns
ns
ns
ns
ns
ns
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd
Power dissipation capacitance per transceiver
Outputs enabled
Outputs disabled
TEST CONDITIONS
CL = 50 pF, f = 1 MHz
TYP UNIT
60
pF
14
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265