Electrical Characteristics (continued)
Over –40ºC to +85°C free-air temperature range, VIN = 12 V, VOUT = 1.5 V, IOUT = IOUT max, FSW = 4 MHz,
External CIN = 2 × 22 µF 25 V 1210 ceramic plus 1 × 100 µF electrolytic (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
PERFORMANCE
ƞ
Efficiency (3)
Transient response(3)
VIN = 12 V, IOUT = 5 A
1 A/µs load step,
25% to 75% IOUT(max),
COUT= 0 µF
5 A/µs load step,
25% to 75% IOUT(max),
COUT= 0 µF
VOUT = 1.2 V, VG = open
VOUT = 1.2 V, VG = 5 V
VOUT = 1.5 V, VG = open
VOUT = 1.5 V, VG = 5 V
VOUT = 1.8 V, VG = open
VOUT = 1.8 V, VG = 5 V
VOUT over/undershoot
Recovery time
VOUT over/undershoot
Recovery time
84.2%
86.2%
85.7%
87.5%
87.4%
89.0%
15
10
30
10
SOFT START
TSS
Internal soft start time(3)
4.1
INTERNAL REGULATOR (VG)
VVG
VG pin output voltage
ENABLE AND UNDER-VOLTAGE LOCK-OUT (EN/UVLO)
4.4
4.8
VEN
EN threshold range
Input current
IEN
Hysteresis current
EN threshold + 50 mV
EN threshold – 50 mV
1.17
1.23
–4
–1
POWER GOOD (PGOOD)
VPGOOD PGOOD thresholds(3)
Minimum VIN for valid
PGOOD (3)
VVOUT falling (Fault)
VVOUT rising (Good)
VVOUT rising (Fault)
VVOUT falling (Good)
VPGOOD ≤ 0.5 V at 100 µA
89%
95%
109%
104%
1.2
PGOOD low voltage
THERMAL SHUTDOWN
IPGOOD = 1.7 mA
0.25
Thermal shutdown threshold
135
Thermal shutdown hysteresis
20
CAPACITANCE
CIN
External input capacitance
COUT
External output capacitance
Ceramic type
Non-ceramic type
Ceramic type
Non-ceramic type
Equivalent series resistance (ESR)
0 (4)
44
0 (4)
100
0 (5)
0 (5)
MAX UNIT
mV
µs
mV
µs
ms
5.0 V
1.27 V
µA
µA
2.75 V
0.3 V
°C
°C
µF
µF
1000(6) µF
2200(6) µF
35 mΩ
(4) Internal to the device, 14.2 µF (nominal) ceramic input capacitance is present. This device does not require additional input capacitance.
If adding additional input capacitance, locate the capacitors close to the device.
(5) Internal to the device, 135 µF (nominal) ceramic output capacitance is present. This device does not require additional output
capacitance to operate. Adding additional output capacitance near the load improves the response of the device to load transients.
(6) The maximum output capacitance listed in the table is the maximum amount that has been tested and validated for proper start-up,
stability, and transient response. It may be possible to operate with additional output capacitance, however, additional validation is
required.