TLE202x-EP, TLE202xA-EP
EXCALIBUR HIGH-SPEED LOW-POWER PRECISION
OPERATIONAL AMPLIFIERS
SGLS235D− FEBRUARY 2004 − REVISED SEPTEMBER 2010
TLE2021 electrical characteristics at specified free-air temperature, VCC = 5 V (unless otherwise
noted)
PARAMETER
TEST CONDITIONS
TLE2021MDREP
TA†
UNIT
MIN TYP MAX
VIO
Input offset voltage
25°C
Full range
120 600
μV
850
αVIO
IIO
Temperature coefficient of input offset voltage
Input offset voltage long-term drift (see Note 4)
Input offset current
VIC = 0,
RS = 50 Ω
Full range
25°C
25°C
Full range
2
0.005
0.2
μV/°C
μV/mo
6
nA
10
IIB
Input bias current
25°C
Full range
25
70
nA
90
VICR Common-mode input voltage range
RS = 50 Ω
0 −0.3
25°C
to
to
3.5
4
V
0
Full range
to
3.2
VOH High-level output voltage
VOL
Low-level output voltage
RL = 10 kΩ
25°C
4 4.3
V
Full range 3.8
25°C
Full range
0.7 0.8
0.95
V
25°C
0.3 1.5
AVD
Large-signal differential voltage amplification
VO = 1.4 V to 4 V, RL = 10 kΩ Full range
0.1
V/μV
CMRR Common-mode rejection ratio
25°C
85 110
VIC = VICRmin,
RS = 50 Ω Full range
80
dB
kSVR Supply-voltage rejection ratio (ΔVCC ± /ΔVIO)
VCC = 5 V to 30 V
25°C
105 120
dB
Full range 100
ICC
ΔICC
Supply current
Supply current change over operating
temperature range
VO = 2.5 V,
No load
25°C
Full range
Full range
170 300
μA
300
9
μA
† Full range is −55°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
6
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265