English
Language : 

TLC2272-Q1_16 Datasheet, PDF (6/43 Pages) Texas Instruments – Advanced LinCMOS Rail-To-Rail Operational Amplifiers
TLC2272-Q1, TLC2272A-Q1, TLC2274-Q1, TLC2274A-Q1
SGLS007F – FEBRUARY 2003 – REVISED MARCH 2016
www.ti.com
TLC2272-Q1 and TLC2272A-Q1 Electrical Characteristics VDD = 5 V (continued)
at specified free-air temperature, VDD = 5 V; TA = 25°C, unless otherwise noted.
PARAMETER
TEST CONDITIONS
kSVR
Supply-voltage rejection ratio
(ΔVDD / ΔVIO)
VDD = 4.4 V to 16 V, VIC = VDD / 2, no load
TA = 25°C
Full Range(1)
IDD
Supply currrent
VO = 2.5 V, no load
TA = 25°C
Full Range(1)
SR
Slew rate at unity gain
VO = 0.5 V to 2.5 V, RL = 10 kΩ (3),
CL = 100 pF(3)
TA = 25°C
Full Range(1)
Vn
Equivalent input noise voltage
f = 10 Hz
f = 1 kHz
VNPP
Peak-to-peak equivalent
input noise voltage
f = 0.1 Hz to 1 Hz
f = 0.1 Hz to 10 Hz
In
Equivalent input noise current
THD+N Total harmonic distortion + noise
Gain-bandwidth product
BOM
Maximum output-swing bandwidth
ts
Settling time
VO = 0.5 V to 2.5 V, f = 20 kHz, RL = 10 kΩ (3)
AV = 1
AV = 10
AV = 100
f = 10 kHz, RL = 10 kΩ (3), CL = 100 pF(3)
VO(PP) = 2 V, AV = 1, RL = 10 kΩ (3), CL = 100 pF(3)
AV = –1, RL = 10 kΩ(3),
Step = 0.5 V to 2.5 V, CL = 100 pF(3)
To 0.1%
To 0.01%
φm
Phase margin at unity gain
Gain margin
RL = 10 kΩ (3), CL = 100 pF(3)
RL = 10 kΩ (3), CL = 100 pF(3)
MIN
TYP
80
95
80
2.2
2.3
3.6
1.7
50
9
1
1.4
0.6
0.0013%
0.004%
0.03%
2.18
1
1.5
2.6
50°
10
MAX UNIT
dB
3
mA
3
V/µs
nV/√Hz
µV
fA/√Hz
MHz
MHz
µs
dB
6.6 TLC2272-Q1 and TLC2272A-Q1 Electrical Characteristics VDD± = ±5 V
at specified free-air temperature, VDD± = ±5 V; TA = 25°C, unless otherwise noted.
PARAMETER
TEST CONDITIONS
MIN
VIO
Input offset voltage
VIC = 0 V, VO = 0 V,
RS = 50 Ω
TLC2272-Q1
TLC2272A-Q1
TLC2272-Q1
TLC2272A-Q1
TA = 25°C
Full Range(1)
αVIO
Temperature coefficient of
input offset voltage
VIC = 0 V, VO = 0 V, RS = 50 Ω
Input offset voltage long-term drift(2) VIC = 0 V, VO = 0 V, RS = 50 Ω
IIO
Input offset current
VIC = 0 V, VO = 0 V, RS = 50 Ω
TA = 25°C
Full Range(1)
IIB
Input bias current
VIC = 0 V, VO = 0 V, RS = 50 Ω
TA = 25°C
Full Range(1)
VICR Common-mode input voltage
RS = 50 Ω; |VIO | ≤ 5 mV
TA = 25°C
Full Range(1)
–5.3
–5
VOM+
Maximum positive peak
output voltage
IO = −20 μA
IO = −200 μA
IO = −1 mA
TA = 25°C
Full Range(1)
TA = 25°C
Full Range(1)
4.85
4.85
4.25
4.25
VOM-
Maximum negative
peak output voltage
VIC = 0 V
IO = 50 μA
IO = 500 μA
IO = 5 mA
TA = 25°C
Full Range(1)
TA = 25°C
Full Range(1)
–4.85
–4.85
–3.5
–3.5
TYP
300
300
2
0.002
0.5
1
0
0
4.99
4.93
4.65
MAX
2500
950
3000
1500
UNIT
µV
μV/°C
μV/mo
60
pA
800
60
pA
800
4
V
3.5
V
–4.99
–4.91
V
–4.1
(1) TA = –40°C to 125°C.
(2) Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated to
TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
6
Submit Documentation Feedback
Copyright © 2003–2016, Texas Instruments Incorporated
Product Folder Links: TLC2272-Q1 TLC2272A-Q1 TLC2274-Q1 TLC2274A-Q1