ELECTRICAL CHARACTERISTICS
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
VOH
IOH = -100 µA
IOH = -4 mA
IOH = -6 mA
IOH = -12 mA
TEST CONDITIONS
VCC
1.65 V to 3.6 V
1.65 V
2.3 V
2.3 V
2.7 V
3V
MIN
VCC - 0.2
1.2
2
1.7
2.2
2.4
TYP(1) MAX UNIT
V
IOH = -24 mA
IOL = 100 µA
IOL = 4 mA
VOL
IOL = 6 mA
IOL = 12 mA
3V
2
1.65 V to 3.6 V
1.65 V
2.3 V
2.3 V
2.7 V
0.2
0.45
0.4
V
0.7
0.4
II
II(hold)
IOZ (3)
ICC
∆ICC
Ci Control inputs
Cio A or B ports
IOL = 24 mA
VI = VCC or GND
VI = 0.58 V
VI = 1.07 V
VI = 0.7 V
VI = 1.7 V
VI = 0.8 V
VI = 2 V
VI = 0 to 3.6 V(2)
VO = VCC or GND
VI = VCC or GND,
One input at VCC - 0.6 V,
VI = VCC or GND
VO = VCC or GND
IO = 0
Other inputs at VCC or GND
3V
3.6 V
1.65 V
1.65 V
2.3 V
2.3 V
3V
3V
3.6 V
3.6 V
3.6 V
3 V to 3.6 V
3.3 V
3.3 V
0.55
±5 µA
25
-25
45
-45
µA
75
-75
±500
±10 µA
40 µA
750 µA
3.5
pF
8.5
pF
(1) All typical values are at VCC = 3.3 V, TA = 25°C.
(2) This is the bus-hold maximum dynamic current. It is the minimum overdrive current required to switch the input from one state to
another.
(3) For I/O ports, the parameter IOZ includes the input leakage current.
TIMING REQUIREMENTS
over recommended operating free-air temperature range (unless otherwise noted) (see Figure 1 through Figure 3)
fclock
tw
tsu
th
Clock frequency
Pulse duration
Setup time
Hold time
CLKEN high
CLK high or low
Data before CLK
CLKEN before CLK
Data after CLK
CLKEN after CLK
VCC = 1.8 V
VCC = 2.5 V
± 0.2 V
MIN MAX MIN MAX
(1)
150
(1)
3.3
(1)
3.3
(1)
1.7
(1)
1.2
(1)
0.6
(1)
1.1
VCC = 2.7 V
VCC = 3.3 V
± 0.3 V
MIN MAX MIN MAX
150
150
3.3
3.3
3.3
3.3
1.9
1.5
1
1
0.6
0.8
0.9
1.1
(1) This information was not available at the time of publication.
UNIT
MHz
ns
ns
ns
6