English
Language : 

SN74ALVC16373_13 Datasheet, PDF (6/11 Pages) Texas Instruments – 16-BIT TRANSPARENT D-TYPE LATCH WITH 3-STATE OUTPUTS
SN74ALVC16373
16ĆBIT TRANSPARENT DĆTYPE LATCH
WITH 3ĆSTATE OUTPUTS
SCAS257B − JANUARY 1993 − REVISED JULY 1995
PARAMETER MEASUREMENT INFORMATION
VCC = 2.5 V " 0.2 V
From Output
Under Test
CL = 50 pF
(see Note A)
500 Ω
500 Ω
4.6 V
S1
Open
GND
TEST
tpd
tPLZ/tPZL
tPHZ/tPZH
S1
Open
4.6 V
GND
Timing
Input
Data
Input
Input
tPLH
Output
LOAD CIRCUIT
1.2 V
tsu
th
1.2 V
1.2 V
VOLTAGE WAVEFORMS
SETUP AND HOLD TIMES
2.3 V
0V
2.3 V
0V
1.2 V
1.2 V
2.3 V
0V
tPHL
1.2 V
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
VOH
1.2 V
VOL
tw
Input 1.2 V
1.2 V
VOLTAGE WAVEFORMS
PULSE DURATION
2.3 V
0V
Output
Control
(low-level
enabling)
tPZL
1.2 V
1.2 V
tPLZ
2.3 V
0V
Output
Waveform 1
S1 at 4.6 V
(see Note B)
Output
Waveform 2
S1 at GND
(see Note B)
tPZH
1.2 V
tPHZ
1.2 V
2.3 V
VOL + 0.3 V
VOL
VOH
VOH − 0.3 V
0V
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES
NOTES: A. CL includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
C. All input pulses are supplied by generators having the following characteristics: PRR v 10 MHz, ZO = 50 Ω, tr v 2.5 ns, tf v 2.5 ns.
D. The outputs are measured one at a time with one transition per measurement.
E. tPLZ and tPHZ are the same as tdis.
F. tPZL and tPZH are the same as ten.
G. tPLH and tPHL are the same as tpd.
Figure 1. Load Circuit and Voltage Waveforms
6
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
• POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443