CY74FCT16823T_15 Datasheet, PDF (6/16 Pages) Texas Instruments – 18-Bit Registers | |||
|
◁ |
CY74FCT16823T
CY74FCT162823T
Switching Characteristics Over the Operating Range[15] (continued)
Parameter
Description
CY74FCT16823CT
CY74FCT162823CT
Condition[16] Min.
Max. Unit
tSU
Set-Up Time
HIGH or LOW, D to CLK
tH
Hold Time
HIGH or LOW, D to CLK
CL=50 pF
2.0
RL=500â¦
1.5
â
ns
â
ns
tSU
Set-Up Time
HIGH or LOW, CLKEN to CLK
3.0
â
ns
tH
Hold Time HIGH or LOW
CLKEN to CLK
0.0
â
ns
tW
CLK Pulse Width
HIGH or LOW
3.3
â
ns
tW
CLR Pulse Width LOW
3.3
â
ns
tREM
Recovery Time
CLR to CLK
6.0
â
ns
tSK(O)
Output Skew[18]
â
0.5
ns
Notes:
15. Minimum limits are speciï¬ed but not tested on Propagation Delays.
16. See âParameter Measurement Informationâ in the General Information section.
17. These limits are speciï¬ed but not tested.
18. Skew between any two outputs of the same package switching in the same direction. This parameter is ensured by design.
Fig.No.[16]
4
4
9
9
5
5
6
â
Ordering Information CY74FCT16823
Speed
(ns)
6.0
10.0
Ordering Code
CY74FCT16823CTPACT
CY74FCT16823CTPVC/PVCT
CY74FCT16823ATPACT
Package
Name
Z56
O56
Z56
Package Type
56-Lead (240-Mil) TSSOP
56-Lead (300-Mil) SSOP
56-Lead (240-Mil) TSSOP
Operating
Range
Industrial
Industrial
Ordering Information CY74FCT162823
Speed
(ns)
6.0
10.0
Ordering Code
74FCT162823CTPACT
CY74FCT162823CTPVC
74FCT162823CTPVCT
74FCT162823ATPACT
Package
Name
Z56
O56
O56
Z56
Package Type
56-Lead (240-Mil) TSSOP
56-Lead (300-Mil) SSOP
56-Lead (300-Mil) SSOP
56-Lead (240-Mil) TSSOP
Operating
Range
Industrial
Industrial
6
|
▷ |