English
Language : 

LM3S6432 Datasheet, PDF (595/696 Pages) Texas Instruments – Stellaris® LM3S6432 Microcontroller
Stellaris® LM3S6432 Microcontroller
Register 10: PWM0 Control (PWM0CTL), offset 0x040
This register configures the PWM signal generation block. The Register Update mode, Debug mode,
Counting mode, and Block Enable mode are all controlled via this register. The block produces the
PWM signals, which can be either two independent PWM signals (from the same counter), or a
paired set of PWM signals with dead-band delays added.
The PWM0 block produces the PWM0 and PWM1 outputs.
PWM0 Control (PWM0CTL)
Base 0x4002.8000
Offset 0x040
Type R/W, reset 0x0000.0000
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
reserved
Type RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
reserved
CmpBUpd CmpAUpd LoadUpd Debug Mode Enable
Type RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
R/W
R/W
R/W
R/W
R/W
R/W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit/Field
31:6
5
4
3
2
1
Name
reserved
CmpBUpd
CmpAUpd
LoadUpd
Debug
Mode
Type
RO
R/W
R/W
R/W
R/W
R/W
Reset
0x00
0
0
0
0
0
Description
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
Comparator B Update Mode
Same as CmpAUpd but for the comparator B register.
Comparator A Update Mode
The Update mode for the comparator A register. When not set, updates
to the register are reflected to the comparator the next time the counter
is 0. When set, updates to the register are delayed until the next time
the counter is 0 after a synchronous update has been requested through
the PWM Master Control (PWMCTL) register (see page 586).
Load Register Update Mode
The Update mode for the load register. When not set, updates to the
register are reflected to the counter the next time the counter is 0. When
set, updates to the register are delayed until the next time the counter
is 0 after a synchronous update has been requested through the PWM
Master Control (PWMCTL) register.
Debug Mode
The behavior of the counter in Debug mode. When not set, the counter
stops running when it next reaches 0, and continues running again when
no longer in Debug mode. When set, the counter always runs.
Counter Mode
The mode for the counter. When not set, the counter counts down from
the load value to 0 and then wraps back to the load value (Count-Down
mode). When set, the counter counts up from 0 to the load value, back
down to 0, and then repeats (Count-Up/Down mode).
June 18, 2012
595
Texas Instruments-Production Data