TNETX3151 Datasheet, PDF (52/65 Pages) Texas Instruments – ThunderSWITCHE 12/3 ETHERNETE SWITCH WITH 12 10-MBIT/S PORTS AND 3 10-/100-MBIT/S PORTS | |||
|
◁ |
TNETX3151
ThunderSWITCH⢠12/3 ETHERNET⢠SWITCH
WITH 12 10-MBIT/S PORTS AND 3 10-/100-MBIT/S PORTS
SPWS048A â MARCH 1998 â REVISED APRIL 1999
10-Mbit/s interface (ports 04â15)
timing requirements (see Notes 3 through 6 and Figure 12)â
NO.
MIN MAX UNIT
1 tc(THxCLK)
Cycle time, THxCLK
50
58 ns
2 Tw(THxCLK)
Pulse duration, THxCLK high or low
23
27 ns
3 tsu(THxSYNC) Setup time, THxSYNC high before THxCLKâ
8
ns
4 tsu(THxCOL) Setup time, THxCOL high before THxCLKâ
8
ns
4 tsu(THxCRS) Setup time, THxCRS high before THxCLKâ
8
ns
4 tsu(THxLINK) Setup time, THxLINK high before THxCLKâ
8
ns
4 tsu(THxRXD) Setup time, THxRXD3âTHxRXD0 valid before THxCLKâ
8
ns
4 tsu(THxRXDV) Setup time, THxRXDV high before THxCLKâ
8
ns
5 th(THxSYNC) Hold time, THxSYNC high after THxCLKâ
8
ns
6 th(THxCOL)
Hold time, THxCOL high after THxCLKâ
8
ns
6 th(THxCRS)
Hold time, THxCRS high after THxCLKâ
8
ns
6 th(THxLINK)
Hold time, THxLINK high after THxCLKâ
8
ns
6 th(THxRXD)
Hold time, THxRXD3âTHxRXD0 valid after THxCLKâ
8
ns
6 th(THxRXV)
Hold time, THxRXDV high after THxCLKâ
8
ns
tr(THxCLK)
Rise time, THxCLK
2 ns
tf(THxCLK)
Fall time, THxCLK
2 ns
â THx = TH1 and TH2
NOTES: 3. The TNETE2008 must supply at least two THxSYNC pulses under normal conditions before driving valid data on the inputs to the
TNETX3151, or before expecting valid data on the outputs from the TNETX3151. This means that at least two full sequences must
be executed; only with the third THxSYNC pulse is valid data presented/expected.
4. At least two clocks must be driven before the deassertion of the system reset signal, and a minimum of two clocks must be driven
after the deassertion of the the system reset signal to ensure complete initialization of the internal circuitry of the TNETX3151 before
there is any valid activity across the interface.
5. For receive data, the TNETE2008 asserts the THxCOL signal during the appropriate slot time if it was asserted for any of the four
bits of data corresponding to that slot time.
6. For receive data, the TNETE2008 asserts the THxRXDV signal only if there are four valid bits of data in the nibble.
operating characteristics over recommended operating conditions (see Notes 3 through 6 and
Figure 12)â
NO.
PARAMETER
MIN MAX UNIT
7 td(THxEN)
Delay time, from THxCLKâ to THxTXENâ
13.5 ns
7 td(THxTXD)
Delay time, from THxCLKâ to THxTXD3âTHxTXD0 valid
13.5 ns
7 td(THxRENEG) Delay time, from THxCLKâ to THxRENEGâ
13.5 ns
8 td(THxTXEN) Delay time, from THxCLKâ to THxTXENâ
0 ns
8 td(THxTXD)
Delay time, from THxCLKâ to THxTXD3âTHxTXD0 invalid
0 ns
8 td(THxRENEG) Delay time, from THxCLKâ to THxRENEGâ
0 ns
â THx = TH1 and TH2
NOTES: 3. The TNETE2008 must supply at least two THxSYNC pulses under normal conditions before driving valid data on the inputs to the
TNETX3151, or before expecting valid data on the outputs from the TNETX3151. This means that at least two full sequences must
be executed; only with the third THxSYNC pulse is valid data presented/expected.
4. At least two clocks must be driven before the deassertion of the system reset signal, and a minimum of two clocks must be driven
after the deassertion of the the system reset signal to ensure complete initialization of the internal circuitry of the TNETX3151 before
there is any valid activity across the interface.
5. For receive data, TNETE2008 asserts the THxCOL signal during the appropriate slot time if it was asserted for any of the four bits
of data corresponding to that slot time.
6. For receive data, the TNETE2008 asserts the THxRXDV signal only if there are four valid bits of data in the nibble.
52
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265
|
▷ |