MSC1211 Datasheet, PDF (50/111 Pages) Texas Instruments – Precision Analog-to-Digital Converter (ADC) and Digital-to-Analog Converters (DACs) with 8051 Microcontroller and Flash Memory
MSC1211, MSC1212
MSC1213, MSC1214
SBAS323G − JUNE 2004 − REVISED OCTOBER 2007
Data Pointer Select (DPS)
7
6
5
4
3
2
SFR 86h
0
0
0
0
0
0
SEL
Data Pointer Select. This bit selects the active data pointer.
bit 0
0: Instructions that use the DPTR will use DPL0 and DPH0.
1: Instructions that use the DPTR will use DPL1 and DPH1.
www.ti.com
1
0
Reset Value
0
SEL
00h
Power Control (PCON)
7
6
5
4
3
2
1
0
Reset Value
SFR 87h
SMOD
0
1
1
GF1
GF0
STOP
IDLE
30h
SMOD
bit 7
GF1
bit 3
GF0
bit 2
STOP
bit 1
IDLE
bit 0
Serial Port 0 Baud Rate Doubler Enable. The serial baud rate doubling function for Serial Port 0.
0: Serial Port 0 baud rate will be a standard baud rate.
1: Serial Port 0 baud rate will be double that defined by baud rate generation equation.
General-Purpose User Flag 1. This is a general-purpose flag for software control.
General-Purpose User Flag 0. This is a general-purpose flag for software control.
Stop Mode Select. Setting this bit halts the oscillator and blocks external clocks. This bit always reads as a 0.
All digital pins and DACs keep their respective output values. Internal REF dies. Exit with RESET.
Idle Mode Select. Setting this bit freezes the CPU, Timer 0, 1, and 2, and the USARTs; other peripherals remain
active. This bit will always be read as a 0. All digital pins and DACs keep their respective output values. Internal REF
remains unchanged. Exit with AI (A6h) and EWU (C6h) interrupts.
50