English
Language : 

TRS3122E Datasheet, PDF (5/28 Pages) Texas Instruments – 1.8 V Low Power Dual RS-232 Transceiver
www.ti.com
6.3 Recommended Operating Conditions
VCC
Charge pump power supply
VL
RIN
DOUT
Logic power supply
RS-232 Receiver interface
RS-232 Transmitter interface
VIL
GPIO Input logic
threshold low
DIN, FORCEOFF, FORCEON
VIH
GPIO Input logic
threshold high
DIN, FORCEOFF, FORCEON
VOZ
ROUT disabled
Operating temperature
TRS3122E
SLLSET7C – MAY 2016 – REVISED MAY 2016
Tripler Mode
Doubler Mode
VL = 5.0 V
VL = 3.3V
VL = 1.8 V
VL = 5.0V
VL = 3.3V
VL = 1.8V
FORCEOFF = 0V
MIN TYP MAX UNIT
1.65 1.8
2
3 3.3 3.6 V
4.5
5 5.5
1.65
-15
VCC
V
15 V
-12
12 V
0
1.7
0
1.1 V
0
0.6
3.3
VL
2.2
VL V
1.2
VL
0
VL V
–40
85 °C
6.4 Thermal Characteristics
THERMAL METRIC
RθJA
RθJCtop
RθJB
ψJT
ψJB
RθJC(bot)
Junction-to-ambient thermal resistance
Junction-to-case (top) thermal resistance
Junction-to-board thermal resistance
Junction-to-top characterization parameter
Junction-to-board characterization parameter
Junction-to-case (bottom) thermal resistance
TRS3122E
RGE
34.2
27.2
11.4
0.4
11.4
3.6
UNIT
°C/W
6.5 Power and Status Electrical Characteristics
VCC = VL = (1.65 V to 2.0 V) & (3.0V to 5.5V), TA = -40°C to 85°C (unless otherwise noted). Typical data is TA = 25°C, VCC =
VL = 3.3V unless otherwise noted.
PARAMETER
TEST CONDITIONS
MIN
TYP MAX UNIT
Icc (Static)
Icc (off)
DIN1 = GND or VL;
DIN2 = GND or VL,
FORCEOFF = VL
FORCEON = VL
FORCEOFF = GND
No load
VCC= 1.65V to 2.0V
VCC= 3.0V to 3.6V
VCC= 4.5V to 5.5V
1.0 1.9
0.7 1.4 mA
0.8 1.9
0.4
10 μA
RIN postive voltage
VIT+
threshold for INVALID
output change
RIN1 = RIN2
RIN negative voltage
VIT-
threshold for INVALID
output change
0.3
2.4
V
-2.4
-0.3
VOH
INVALID high-level
output voltage
IOH = -1 mA, FORCEON = GND, FORCEOFF = VL
VL-0.4
VL-0.08
VL V
VOL
INVALID low-level
output voltage
IOL = 1.6 mA, FORCEON = GND, FORCEOFF = VL
0
0.06 0.4 V
Copyright © 2016, Texas Instruments Incorporated
Product Folder Links: TRS3122E
Submit Documentation Feedback
5