TPS75201M-EP Datasheet, PDF (5/30 Pages) Texas Instruments – FAST-TRANSIENT-RESPONSE 2-A LOW-DROPOUT VOLTAGE REGULATOR WITH RESET | |||
|
◁ |
TPS75201MÄEP
FASTÄTRANSIENTÄRESPONSE 2ÄA LOWÄDROPOUT VOLTAGE REGULATOR
WITH RESET
SGLS325 â JANUARY 2006
absolute maximum ratings over operating junction temperature range (unless otherwise noted)Ä
Input voltage rangeâ¡, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . â0.3 V to 5.5 V
Voltage range at EN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . â0.3 V to 16.5 V
Maximum RESET voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16.5 V
Peak output current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Internally limited
Output voltage, VO (OUTPUT, FB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See dissipation rating table
Operating virtual junction temperature range, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . â55°C to 125°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . â65°C to 150°C
ESD rating, Human-Body Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 kV
â Stresses beyond those listed under âabsolute maximum ratingsâ may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under ârecommended operating conditionsâ is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
â¡ All voltage values are with respect to network terminal ground.
DISSIPATION RATING TABLE â FREE-AIR TEMPERATURES
PACKAGE
PWP§
AIR FLOW
(CFM)
0
300
TA < 25°C
POWER RATING
2.9 W
4.3 W
DERATING FACTOR
ABOVE TA = 25°C
23.5 mW/°C
34.6 mW/°C
TA = 70°C
TA = 85°C
POWER RATING POWER RATING
1.9 W
1.5 W
2.8 W
2.2 W
PWP¶
0
300
3W
7.2 W
23.8 mW/°C
57.9 mW/°C
1.9 W
4.6 W
1.5 W
3.8 W
§ This parameter is measured with the recommended copper heat- sink pattern on a one-layer PCB, 5-in à 5-in PCB, 1-oz copper,
2-in à 2-in coverage (4 in2).
¶ This parameter is measured with the recommended copper heat-sink pattern on an eight-layer PCB, 1.5-in à 2-in PCB, 1-oz
copper with layers 1, 2, 4, 5, 7, and 8 at 5% coverage (0.9 in2), and layers 3 and 6 at 100% coverage (6 in2). For more information,
refer to TI technical brief SLMA002.
recommended operating conditions
MIN MAX UNIT
Input voltage, VI#
2.7
5V
Output voltage range, VO
1.5
5V
Output current, IO
0 2.0 A
Operating virtual junction temperature, TJ
â55 125 °C
# To calculate the minimum input voltage for your maximum output current, use the following equation: VI(min) = VO(max) + VDO(max load).
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265