TLE202X-Q1_15 Datasheet, PDF (5/41 Pages) Texas Instruments – EXCALIBUR HIGH-SPEED LOW-POWER PRECISION OPERATIONAL AMPLIFIERS
TLE202x-Q1, TLE202xA-Q1
EXCALIBUR HIGH-SPEED LOW-POWER PRECISION
OPERATIONAL AMPLIFIERS
SGLS199B − JANUARY 2004 − REVISED APRIL 2008
TLE2021 electrical characteristics at specified free-air temperature, VCC = 5 V (unless otherwise
noted)
PARAMETER
VIO
αVIO
IIO
Input offset voltage
Temperature
coefficient of input
offset voltage
Input offset voltage
long-term drift
(see Note 4)
Input offset current
IIB
Input bias current
TEST CONDITIONS
TA†
25°C
Full range
Full range
VIC = 0,
RS = 50 Ω
25°C
25°C
Full range
25°C
Full range
VICR
Common-mode input
voltage range
RS = 50 Ω
25°C
Full range
High-level output
VOH
voltage
Low-level output
VOL
voltage
RL = 10 kΩ
25°C
Full range
25°C
Full range
TLE2021-Q1
MIN TYP MAX
120 600
800
2
0.005
0.2
6
10
25
70
90
0 −0.3
to
to
3.5
4
0
to
3.2
4 4.3
3.8
0.7 0.8
0.95
TLE2021A-Q1
MIN TYP MAX
100 400
550
UNIT
µV
2
µV/°C
0.005
µV/mo
0.2
6
nA
10
25
70
nA
90
0 −0.3
to
to
3.5
4
V
0
to
3.2
4 4.3
V
3.8
0.7 0.8
V
0.95
Large-signal
AVD
differential
voltage amplification
Common-mode
CMRR rejection ratio
25°C
VO = 1.4 V to 4 V, RL = 10 kΩ
Full range
VIC = VICRmin,
25°C
RS = 50 Ω Full range
0.3 1.5
0.1
85 110
80
0.3 1.5
0.1
85 110
80
V/µV
dB
kSVR
ICC
∆ICC
Supply-voltage
rejection ratio
(∆VCC ± /∆VIO)
VCC = 5 V to 30 V
Supply current
Supply current
VO = 2.5 V,
change over operating
temperature range
No load
25°C
105 120
105 120
dB
Full range 100
100
25°C
Full range
170 300
300
170 300
µA
300
Full range
9
9
µA
† Full range is −40°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265