electrical characteristics at specified free-air temperature, VDD± = ±5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TLC2801Z
TA†
UNIT
MIN TYP MAX
VIO
Input offset voltage
25°C
Full range
100 500
µV
1500
αVIO Temperature coefficient of input offset voltage
– 55°C to
150°C
4
µV/°C
Input offset voltage long-term drift
(see Note 4)
VIC = 0,
RS = 50 Ω
25°C
0.001 0.005 µV/mo
IIO
Input offset current
25°C
Full range
0.5
pA
3 nA
IIB
Input bias current
25°C
Full range
1
pA
30 nA
VICR Common-mode input voltage range
RS = 50 Ω
–5
Full range
to
V
2.7
VOM +
VOM –
Maximum positive peak output voltage swing
RL = 10 kΩ
Maximum negative peak output voltage swing
25°C
4.7 4.8
V
Full range 4.5
25°C
– 4.7 – 4.9
V
Full range – 4.5
VO = ± 4 V, RL = 500 kΩ
AVD
Large-signal differential voltage amplification
VO = ± 4 V, RL = 10 kΩ
25°C
300 460
Full range 100
25°C
50 100
Full range
15
V/mV
CMRR Common-mode rejection ratio
VO = 0,
RS = 50 Ω
VIC = VICRmin,
25 °C
Full range
90 115
85
dB
25°C
90 110
kSVR Supply-voltage rejection ratio (∆VDD ± /∆VIO) VDD ± = ± 2.3 V to ± 8 V
Full range
85
dB
IDD
Supply current
VO = 0,
No load
25°C
Full range
1.1 1.5
mA
1.5
operating characteristics at specified free-air temperature, VDD± = ±5 V
PARAMETER
TEST CONDITIONS
TA†
TLC2801Z
UNIT
MIN TYP MAX
SR
Slew rate unity gain
VO = ± 2.3 V, RL = 10 kΩ,
CL = 100 pF
25 °C
Full range
2 2.7
1
V/µs
Vn
Equivalent input noise voltage
f = 10 Hz
f = 1 kHz
25°C
18
35
nV/√Hz
8
15
VN(PP) Peak-to-peak equivalent input noise voltage
f = 0.1 to 1 Hz
f = 0.1 to 10 Hz
25°C
0.5
µV
0.7
In
Equivalent input noise current
25°C
0.6
fA/√Hz
Gain-bandwidth product
f = 10 kHz, RL = 10 kΩ,
CL = 100 pF
25°C
1.9
MHz
φm
Phase margin at unity gain
RL = 10 kΩ, CL = 100 pF
25°C
48°
† Full range is – 40°C to 150°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3–5