English
Language : 

TL604IP Datasheet, PDF (5/9 Pages) Texas Instruments – P-MOS ANALOG SWITCHES
TL601, TL604, TL607, TL610
P-MOS ANALOG SWITCHES
D2161, JUNE 1976 — REVISED OCTOBER 1986
PARAMETER MEASUREMENT INFORMATION
Figure 1 shows power supply boundary conditions for proper operation of the TL601 Series. The range of
operation for supply VCC+ from 5 V to 25 V is shown on the vertical axis. The range of VCC − from − 5 V to
−25 V is shown on the horizontal axis. A recommended 30-V maximum voltage differential from VCC+ to VCC −
governs the maximum VCC+ for a chosen VCC− (or vice versa). A minimum recommended difference of 15 V
from VCC+ to VCC − and the boundaries shown in Figure 1 allow the designer to select the proper combinations
of the two supplies.
The designer-selected VCC+ supply value for a chosen VCC− supply value limits the maximum input voltage that
can be applied to either switch terminal; that is, the input voltage should be between VCC − + 8 V and VCC+ to
keep the on-state resistance within specified limits.
RECOMMENDED COMBINATIONS
OF SUPPLY VOLTAGES
30
25
20
15
SAFE
AREA
10
5
0
−30 −25
−20 −15
−10
−5
0
VCC − — Supply Voltage — V
Figure 1
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
5