English
Language : 

TL4050_16 Datasheet, PDF (5/32 Pages) Texas Instruments – PRECISION MICROPOWER SHUNT VOLTAGE REFERENCE
TL4050
www.ti.com........................................................................................................................................................ SLOS486A – JUNE 2007 – REVISED AUGUST 2009
FUNCTIONAL BLOCK DIAGRAM
CATHODE
+
_
ANODE
ABSOLUTE MAXIMUM RATINGS(1)
over free-air temperature range (unless otherwise noted)
IZ
Continuous cathode current
θJA
Package thermal impedance(2)(3)
TJ
Operating virtual junction temperature
Tstg
Storage temperature range
DBV package
DCK package
MIN
MAX UNIT
–10
20 mA
206
°C/W
252
150 °C
–65
150 °C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating
Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) Maximum power dissipation is a function of TJ(max), θJA, and TA. The maximum allowable power dissipation at any allowable ambient
temperature is PD = (TJ(max) – TA)/θJA. Operating at the absolute maximum TJ of 150°C can affect reliability.
(3) The package thermal impedance is calculated in accordance with JESD 51-7.
RECOMMENDED OPERATING CONDITIONS
IZ Cathode current
TA Free-air temperature
(1) See parametric tables
I temperature
Q temperature
MIN
MAX UNIT
(1)
15 mA
–40
85
°C
–40
125
Copyright © 2007–2009, Texas Instruments Incorporated
Product Folder Link(s): TL4050
Submit Documentation Feedback
5