English
Language : 

TCA9517A Datasheet, PDF (5/17 Pages) Texas Instruments – LEVEL-TRANSLATING I2C BUS REPEATER
TCA9517A
www.ti.com
SCPS245A – DECEMBER 2012 – REVISED APRIL 2013
ELECTRICAL CHARACTERISTICS
VCCB = 2.7 V to 5.5 V, GND = 0 V, TA = –40°C to 85°C (unless otherwise noted)
PARAMETER
TEST CONDITIONS
VCCB
VIK
Input clamp voltage
II = –18 mA
2.7 V to 5.5 V
VOL
Low-level output
voltage
SDAB, SCLB
IOL = 100 μA or 6 mA,
VILA = VILB = 0 V
2.7 V to 5.5 V
SDAA, SCLA IOL = 6 mA
Low-level input voltage
VOL – VILc below low-level output SDAB, SCLB guaranteed by design
voltage
2.7 V to 5.5 V
VILC
SDA and SCL low-level
input voltage contention
SDAB, SCLB
2.7 V to 5.5 V
Both channels low,
SDAA = SCLA = GND and
ICC
Quiescent supply current for VCCA
SDAB = SCLB = open, or
SDAA = SCLA = open and
SDAB = SCLB = GND
ICC
Quiescent supply current
Both channels high,
SDAA = SCLA = VCCA and
SDAB = SCLB = VCCB and
EN = VCCB
Both channels low,
SDAA = SCLA = GND and
SDAB = SCLB = open
5.5 V
In contention,
SDAA = SCLA = GND and
SDAB = SCLB = GND
SDAB, SCLB VI = VCCB
VI = 0.2 V
II
Input leakage current
SDAA, SCLA VI = VCCB
VI = 0.2 V
EN
VI = VCCB
VI = 0.2 V
IOH
High-level output
leakage current
SDAB, SCLB
SDAA, SCLA VO = 3.6 V
2.7 V to 5.5 V
2.7 V to 5.5 V
EN
VI = 3 V or 0 V
CI
Input capacitance
SCLA, SCLB VI = 3 V or 0 V
3.3 V
3.3 V
0V
CIO
Input/output
capacitance
SDAA, SDAB VI = 3 V or 0 V
3.3 V
0V
MIN TYP MAX UNIT
–1.2 V
0.45 0.52
0.1
0.6
V
0.2
70
mV
0.45
V
1 mA
1.5
5
1.5
5 mA
3
5
±1
10
±1
μA
10
±1
–10
–30
10
μA
10
6
10
8
13 pF
7
11
8
13
pF
7
11
TIMING REQUIREMENTS
over recommended operating free-air temperature range (unless otherwise noted)
tsu
Setup time, EN high before Start condition(1)
th
Hold time, EN high after Stop condition(1)
(1) EN should change state only when the global bus and the repeater port are in an idle state.
MIN
MAX UNIT
100
ns
100
ns
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: TCA9517A
Submit Documentation Feedback
5