English
Language : 

LMH6715QML Datasheet, PDF (5/20 Pages) Texas Instruments – Dual Wideband Video Op Amp
DC Parameter Drift Values
The following conditions apply, unless otherwise specified.
Deltas not required on B Level product. Deltas required for S Level product at Group B5 only, or as specified on the Internal
Processing Instructions (IPI).
Symbol Parameter
Conditions
Notes Min Max Unit
Sub-
groups
IBN
Input Bias Current, Noninverting
IBI
Input Bias Current, Inverting
VIO
Input Offset Voltage
ICC
Supply Current
RL = ∞
(Note 4) -1.2 +1.2
μA
1
(Note 4) -2.0 +2.0
μA
1
(Note 4) -1.0 +1.0
mV
1
(Note 4) -1.0 +1.0
mA
1
Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is
functional, but do not guarantee specific performance limit s. For guaranteed specifications and test conditions, see the Electrical Characteristics. The guaranteed
specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test
conditions.
Note 2: The maximum power dissipation must be derated at elevated temperatures and is dictated by TJmax (maximum junction temperature), θJA (package
junction to ambient thermal resistance), and TA (ambient temperature). The maximum allowable power dissipation at any temperature is PDmax = (TJmax - TA)/
θJA or the number given in the Absolute Maximum Ratings, whichever is lower.
Note 3: Human body model, 1.5kΩ in series with 100 pF.
Note 4: If not tested, shall be guaranteed to the limits specified in table 1 herein.
Note 5: Group A testing only.
Note 6: Pre and post irradiation limits are identical to those listed under electrical characteristics. These parts may be dose rate sensitive in a space environment
and demonstrate enhanced low dose rate effect. Radiation end point limits for the noted parameters are guaranteed only for the conditions as specified in MIL-
STD-883, Method 1019.
www.national.com
4