English
Language : 

JM38510-10902BCA Datasheet, PDF (5/19 Pages) Texas Instruments – DUAL PRECISION TIMERS
www.ti.com
Operating Characteristics
VCC = 5 V and 15 V
PARAMETER
TEST
CONDITIONS (1)
Initial error of timing
interval (2)
Temperature
coefficient of timing
interval
Supply voltage
sensitivity of timing
interval
Each timer,
monostable (3)
Each timer, astable(5)
Timer 1 – Timer 2
Each timer,
monostable (3)
Each timer, astable(5)
Timer 1 – Timer 2
Each timer,
monostable (3)
Each timer, astable(5)
Timer 1 – Timer 2
Output-pulse rise time
Output-pulse fall time
TA = 25°C
TA = MIN to MAX
TA = 25°C
CL = 15 pF,
TA = 25°C
CL = 15 pF,
TA = 25°C
NA556, NE556, SA556, SE556
DUAL PRECISION TIMERS
SLFS023G – APRIL 1978 – REVISED JUNE 2006
NA556
NE556
SA556
MIN TYP
1
2.25%
±1
50
150
±10
0.1
0.3
±0.2
100
MAX
3
0.5
300
100
300
SE556
MIN TYP
0.5
1.5%
±0.5
30
90
±10
0.05
0.15
±0.1
100
UNIT
MAX
1.5 (4)
100 (4)
ppm/°C
0.2 (4)
%/V
200(4) ns
100 200(4) ns
(1) For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
(2) Timing-interval error is defined as the difference between the measured value and the average value of a random sample from each
process run.
(3) Values specified are for a device in a monostable circuit similar to Figure 2, with the following component values: RA = 2 kΩ to 100 kΩ,
C = 0.1 µF.
(4) On products compliant to MIL-PRF-38535, this parameter is not production tested.
(5) Values specified are for a device in an astable circuit similar to Figure 1, with the following component values: RA = 1 kΩ to 100 kΩ,
C = 0.1 µF.
Submit Documentation Feedback
5