English
Language : 

DS481_14 Datasheet, PDF (5/17 Pages) Texas Instruments – Low Power RS-485/RS-422 Multipoint Transceiver with Sleep Mode
DS481
www.ti.com
SNLS131B – JULY 2000 – REVISED MARCH 2013
Switching Characteristics
Over Supply Voltage and Operating Temperature Ranges, unless otherwise specified (1) (2) (3)
Parameter
Test Conditions
Min
Typ
tPLHD
tPHLD
tSKEW
tr
tf
tZH
tZL
tLZ
tHZ
tPSH
Driver Differential Propagation Delay—Low to High
Driver Differential Propagation Delay—High to Low
Differential Skew |tPHLD − tPLHD|
Driver Rise Time
Driver Fall Time
Driver Enable to Output High
Driver Enable to Output Low
Driver Disable from Output Low
Driver Disable from Output High
Driver Enable from Sleep
Mode to Output High
RL = 54Ω, CL = 100 pF
CL = 100 pF
CL = 100 pF
CL = 15 pF
CL = 15 pF
CL = 100 pF
(4)(Figure 6, Figure 7)
10
40
10
39
0
1
3
25
3
25
50
65
80
80
70
98
tPSL
Driver Enable from Sleep
Mode to Output Low
CL = 100 pF
(4)(Figure 8 ,Figure 9)
70
98
tPLHD
tPHLD
tSKEW
tZH
tZL
tLZ
tHZ
tPSH
Receiver Differential Propagation Delay—Low to High CL = 15 pF (RO)
Receiver Differential Propagation Delay—High to Low
Differential Skew |tPHLD − tPLHD|
Receiver Enable to Output High
Receiver Enable to Output Low
CL = 15 pF
Receiver Disable from Output Low
Receiver Disable from Output High
Receiver Enable from Sleep
Mode to Output High
CL = 15 pF
(4)(Figure 12, Figure 14)
30
190
30
210
0
20
45
40
50
55
70
97
tPSL
tSLEEP
Receiver Enable from Sleep
Mode to Output Low
Time to Sleep (Device)
fmax
Maximum Data Rate
CL = 15 pF
(4)(Figure 12, Figure 13)
DE = L and RE (5) = H
(Figure 15)
(6)
70
95
50
2.0
Max
Units
80
ns
80
ns
10
ns
50
ns
50
ns
200
ns
200
ns
200
ns
200
ns
250
ns
250
ns
400
ns
400
ns
50
ns
150
ns
150
ns
150
ns
150
ns
250
ns
250
ns
600
ns
Mbps
(1) All typicals are given for: VCC = +5.0V, TA = +25°C.
(2) f = 1 MHz, tr and tf ≤ 6 ns, ZO = 50Ω.
(3) CL includes jig and probe capacitance.
(4) For enable from sleep mode delays DE = L and RE = H for greater than 600 ns prior to test (device is in sleep mode). RE is Non
Terminated, Open Input only.
(5) Non Terminated, Open Input only
(6) fmax is the guaranteed data rate for 50 ft of twisted pair cable. f max may be conservatively determined from the ratio of driver transition
time (tr) to the data rate unit interval (1/fmax). Using a 10% ratio yields fmax = (0.1)/50 ns = 2.0 Mb/s. Higher data rates may be supported
by allowing larger ratios.
Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: DS481
Submit Documentation Feedback
5