English
Language : 

TLE2141-Q1 Datasheet, PDF (4/23 Pages) Texas Instruments – Excalibur™ LOW-NOISE HIGH-SPEED PRECISION OPERATIONAL AMPLIFIERS
TLE2141-Q1
SLOS525 – SEPTEMBER 2011
www.ti.com
ABSOLUTE MAXIMUM RATINGS(1)
over operating free-air temperature range (unless otherwise noted)
VCC+
VCC–
VID
VI
II
IO
θJA
TA
Tstg
Supply voltage(2)
Supply voltage
Differential input voltage(3)
Input voltage range (any input)
Input current (each input)
Output current
Total current into VCC+
Total current out of VCC–
Duration of short-circuit current at (or below) 25°C(4)
Package thermal impedance(5) (6)
D package (8 pin)
Operating free-air temperature range
Storage temperature range
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds
VALUE
22
–22
±44
VCC+ to (VCC– – 0.3)
±1
±80
80
80
Unlimited
97.1
–40 to 125
–65 to 150
260
UNIT
V
V
V
V
mA
mA
mA
mA
°C/W
°C
°C
°C
(1) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating
conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential voltages, are with respect to the midpoint between VCC+ and VCC–.
(3) Differential voltages are at IN+ with respect to IN–. Excessive current flows, if input, are brought below VCC– – 0.3 V.
(4) The output may be shorted to either supply. Temperature and/or supply voltages must be limited to ensure that the maximum dissipation
rating is not exceeded.
(5) Maximum power dissipation is a function of TJ(max), θJA, and TA. The maximum allowable power dissipation at any allowable ambient
temperature is PD = (TJ(max) – TA)/θJA. Operating at the absolute maximum TJ of 150°C can affect reliability.
(6) The package thermal impedance is calculated in accordance with JESD 51-7.
RECOMMENDED OPERATING CONDITIONS
VCC±
VIC
TA
Supply voltage
Common-mode input voltage
Operating free-air temperature
VCC = 5 V
VCC± = ±15 V
MIN
MAX UNIT
±2
±22 V
0
2.7
V
–15
12.7
–40
125 °C
4
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated