English
Language : 

TL103W_16 Datasheet, PDF (4/16 Pages) Texas Instruments – Dual Operational Amplifiers With Internal Reference
TL103W, TL103WA
SLOS437L – APRIL 2004 – REVISED FEBRUARY 2016
www.ti.com
6 Specifications
6.1 Absolute Maximum Ratings(1)
over operating free-air temperature range (unless otherwise noted)
VCC Supply voltage
VID Operational amplifier input differential voltage
VI Operational amplifier input voltage range
IKA Voltage reference cathode current
TJ Maximum junction temperature
Tstg Storage temperature range
MIN MAX UNIT
36 V
36 V
–0.3
36 V
100 mA
150 °C
–65
150 °C
(1) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating
conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability
6.2 ESD Ratings
V(ESD) Electrostatic discharge
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001(1)
Charged-device model (CDM), per JEDEC specification JESD22-
C101 (2)
VALUE
±2500
±1000
(1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(2) JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.
UNIT
V
6.3 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
VIN Supply voltage
IK Cathode current
TA Operating free-air temperature
MIN MAX UNIT
3
32 V
1
100 mA
–40
105 °C
6.4 Thermal Information
THERMAL METRIC(1)
TL103W / TL103W
D (SOIC)
UNIT
8 PINS
RθJA
Junction-to-ambient thermal resistance
97
°C/W
(1) For more information about traditional and new thermal metrics, see the Semiconductor and IC Package Thermal Metrics application
report, SPRA953.
4
Submit Documentation Feedback
Copyright © 2004–2016, Texas Instruments Incorporated
Product Folder Links: TL103W TL103WA