English
Language : 

TL074QDREP Datasheet, PDF (4/19 Pages) Texas Instruments – LOW-NOISE JFET-INPUT OPERATIONAL AMPLIFIER
TL072-EP, TL074-EP
SLOS747F – OCTOBER 2011 – REVISED DECEMBER 2012
www.ti.com
ELECTRICAL CHARACTERISTICS
VCC± = ±15 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS(1)
VIO
Input offset voltage
VO = 0, RS = 50 Ω
αVIO
Temperature coefficient
of input offset voltage
VO = 0, RS = 50 Ω
IIO
Input offset current
VO = 0
IIB
Input bias current
VO = 0
VICR
VOM
AVD
B1
ri
CMRR
kSVR
ICC
VO1/VO2
Common-mode input
voltage range
Maximum peak output
voltage swing
Large-signal differential
voltage amplification
RL = 10 kΩ
RL ≥ 10 kΩ
RL ≥ 2 kΩ
VO = ±10 V, RL ≥ 2 kΩ
Unity-gain bandwidth
Input resistance
Common-mode
rejection ratio
Supply-voltage rejection
ratio (ΔVCC±/ΔVIO)
Supply current (each
amplifier)
VIC = VICRmin,
VO = 0, RS = 50 Ω
VCC = ±9 V to ±15 V,
VO = 0, RS = 50 Ω
VO = 0, No load
Crosstalk attenuation AVD = 100
TA (2)
25°C
Full range
Full range
25°C
125°C
25°C
125°C
25°C
25°C
Full range
25°C
Full range
25°C
25°C
25°C
25°C
25°C
25°C
TL072
TL074
UNIT
MIN
TYP
MAX MIN
TYP
MAX
3
6
8
3
6
mV
8
18
18
μV/°C
5
100
2
65
200
20
5
100 pA
2 nA
65
200 pA
20 nA
±11 –12 to 15
±11 –12 to 15
V
±12
±13.5
±12
±10
35
200
15
3
1012
±12
±13.5
±12
±10
35
200
15
3
1012
V
V/mV
MHz
Ω
80
86
80
86
dB
80
86
80
86
dB
1.4
2.5
1.4
2.5 mA
120
120
dB
(1) Input bias currents of an FET-input operational amplifier are normal junction reverse currents, which are temperature sensitive, as
shown in Figure 3. Pulse techniques must be used that will maintain the junction temperature as close to the ambient temperature as
possible.
(2) All characteristics are measured under open-loop conditions with zero common-mode voltage, unless otherwise specified. Full range is
TA = –40°C to 125°C for TL07xQ and TA = -55°C to 125°C for TL07xM.
OPERATING CHARACTERISTICS
VCC± = ±15 V, TA= 25°C
PARAMETER
TEST CONDITIONS
SR
tr
Vn
In
THD
Slew rate at unity
gain
Rise-time overshoot
factor
VI = 10 V,
CL = 100 pF,
VI = 20 V,
CL = 100 pF,
Equivalent input noise
voltage
RS = 20 Ω
Equivalent input noise
current
RS = 20 Ω,
Total harmonic
distortion
VIrms = 6 V,
RL ≥ 2 kΩ,
f = 1 kHz,
RL = 2 kΩ,
See Figure 1
RL = 2 kΩ,
See Figure 1
f = 1 kHz
f = 10 Hz to 10 kHz
f = 1 kHz
AVD = 1,
RS ≤ 1 kΩ,
TL072
MIN TYP MAX
8
13
0.1
20
18
4
0.01
TL074
UNIT
MIN TYP MAX
8
13
V/μs
0.1
μs
20
%
18
nV/√Hz
4
μV
0.01
pA/√Hz
0.003
0.003
%
4
Submit Documentation Feedback
Copyright © 2011–2012, Texas Instruments Incorporated
Product Folder Links: TL072-EP TL074-EP