absolute maximum ratings over operating free-air temperature (unless otherwise noted)†
Supply voltage, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage: ’14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
’LS14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Package thermal impedance, θJA (see Note 2): D package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86°C/W
DB package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96°C/W
N package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80°C/W
NS package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76°C/W
Storage temperaturerange, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. Voltage values are with respect to network ground terminal.
2. The package termal impedance is calculated in accordance with JESD 51-7
recommended operating conditions
VCC
IOH
IOL
TA
Supply voltage
High-level output current
Low-level output current
Operating free-air temperature
SN5414
MIN NOM MAX
4.5
5 5.5
–0.8
16
–55
125
SN7414
MIN NOM MAX
4.75
5 5.25
–0.8
16
0
70
UNIT
V
mA
mA
°C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS‡
SN5414
SN7414
MIN TYP§
VT+
VT–
Hysteresis
(VT+ – VT–)
VCC = 5 V
VCC = 5 V
VCC = 5 V
1.5 1.7
0.6 0.9
0.4 0.8
VIK
VCC = MIN,
II = –12 mA
VOH
VCC = MIN,
VI = 0.6 V,
IOH = –0.8 mA
2.4 3.4
VOL
VCC = MIN,
VI = 2 V,
IOL = 16 mA
0.2
IT+
VCC = 5 V,
VI = VT+
–0.43
IT–
VCC = 5 V,
VI = VT–
–0.56
II
VCC = MAX,
VI = 5.5 V
IIH
VCC = MAX,
VIH = 2.4 V
IIL
VCC = MAX,
VIL = 0.4 V
–0.8
IOS¶
VCC = MAX
–18
ICCH
VCC = MAX
22
ICCL
VCC = MAX
39
‡ For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
§ All typical values are at VCC = 5 V, TA = 25°C.
¶ Not more than one output should be shorted at a time.
MAX
2
1.1
–1.5
0.4
1
40
–1.2
–55
36
60
UNIT
V
V
V
V
V
V
mA
mA
mA
µA
mA
mA
mA
mA
4