English
Language : 

OPA134 Datasheet, PDF (4/22 Pages) Burr-Brown (TI) – High Performance AUDIO OPERATIONAL AMPLIFIERS TM
OPA134, OPA2134, OPA4134
SBOS058A – DECEMBER 1997 – REVISED OCTOBER 2015
NAME
V–
+In D
–In D
Out D
PIN
OPA2134
NO.
4
—
—
—
Pin Functions: OPA2134 and OPA4134 (continued)
OPA4134
NO.
11
12
13
14
I/O
DESCRIPTION
—
Negative power supply
I
Noninverting input channel D
I
Inverting input channel D
O
Output channel D
www.ti.com
6 Specifications
6.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted) (1)
MIN
MAX
UNIT
Supply voltage, V+ to V–
36
V
Input voltage
Output short circuit(2)
(V–) –0.7 (V+) +0.7
V
Continuous
Operating temperature
–40
125
°C
Junction temperature
150
°C
Lead temperature (soldering, 10 s)
300
°C
Tstg
Storage temperature
–55
125
°C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended
Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) Short-circuit to ground, one amplifier per package.
6.2 ESD Ratings
OPA134 in PDIP and SOIC Package, OPA2134 and OPA4134 in PDIP Package
V(ESD) Electrostatic discharge
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001(1)
OPA2134 in SOIC Package
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001(1)
V(ESD) Electrostatic discharge
Charged-device model (CDM), per JEDEC specification JESD22-
C101 (2)
OPA4134 in SOIC Package
V(ESD) Electrostatic discharge
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001(1)
Charged-device model (CDM), per JEDEC specification JESD22-
C101 (2)
VALUE
±2000
±2000
±500
±2000
±200
(1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(2) JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.
UNIT
V
V
V
6.3 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
VS
Supply voltage, VS = (V+) – (V–)
TA
Specified temperature
MIN
NOM
MAX UNIT
±2.5
±15
±18
V
–40
85
°C
4
Submit Documentation Feedback
Copyright © 1997–2015, Texas Instruments Incorporated
Product Folder Links: OPA134 OPA2134 OPA4134