English
Language : 

OPA132 Datasheet, PDF (4/30 Pages) Burr-Brown (TI) – High Speed FET-INPUT OPERATIONAL AMPLIFIERS
OPA132, OPA2132, OPA4132
SBOS054B – JANUARY 1995 – REVISED SEPTEMBER 2015
NAME
+In C
V–
+In D
–In D
Out D
PIN
OPA2132
NO.
–
4
–
–
–
Pin Functions OPA2132 and OPA4132 (continued)
OPA4132
I/O
NO.
DESCRIPTION
10
I
Noninverting input channel C
11
—
Negative power supply
12
I
Noninverting input channel D
13
I
Inverting input channel D
14
O
Output channel D
www.ti.com
6 Specifications
6.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted) (1)
MIN
MAX
UNIT
Supply voltage, V+ to V–
36
V
Input voltage
Output short-circuit(2)
(V–) –0.7 (V+) +0.7
V
Continuous
Operation temperature
–40
125
°C
Junction temperature
150
°C
Tstg
Storage temperature
–55
125
°C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended
Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) Short-circuit to ground, one amplifier per package.
6.2 ESD Ratings
OPA132 in PDIP and SOIC Package, OPA2132 and OPA4132 in PDIP Package
V(ESD) Electrostatic discharge
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001(1)
OPA2132 in SOIC Package
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001(1)
V(ESD) Electrostatic discharge
Charged-device model (CDM), per JEDEC specification JESD22-
C101 (2)
OPA4132 in SOIC Package
V(ESD) Electrostatic discharge
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001(1)
Charged-device model (CDM), per JEDEC specification JESD22-
C101 (2)
VALUE
±2000
±2000
±500
±2000
±200
(1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(2) JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.
UNIT
V
V
V
6.3 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
VS
Supply voltage, VS = (V+) – (V–)
TA
Specified temperature range
MIN
NOM
MAX UNIT
±2.5
±15
±18
V
–40
85
°C
4
Submit Documentation Feedback
Copyright © 1995–2015, Texas Instruments Incorporated
Product Folder Links: OPA132 OPA2132 OPA4132