English
Language : 

LP2980-N_16 Datasheet, PDF (4/30 Pages) Texas Instruments – Micropower 50-mA Ultra Low-Dropout Regulator in SOT-23 Package
LP2980-N
SNOS733O – APRIL 2000 – REVISED JUNE 2015
www.ti.com
6.2 ESD Ratings
V(ESD)
Electrostatic
discharge
Human-body model (HBM), per
ANSI/ESDA/JEDEC JS-001(1)
All pins except 3 and 4
Pins 3 and 4
VALUE
±2000
±1000
(1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
UNIT
V
6.3 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
Operating junction temperature
Input supply voltage (operating)
MIN
MAX UNIT
−40
125
°C
2.1
16
V
6.4 Thermal Information
THERMAL METRIC(1)
LP2980-N
DBV
UNIT
5 PINS
RθJA
RθJC(top)
RθJB
ψJT
ψJB
Junction-to-ambient thermal resistance
Junction-to-case (top) thermal resistance
Junction-to-board thermal resistance
Junction-to-top characterization parameter
Junction-to-board characterization parameter
175.7
78
30.8
2.8
30.3
°C/W
(1) For more information about traditional and new thermal metrics, see the Semiconductor and IC Package Thermal Metrics application
report, SPRA953.
6.5 Electrical Characteristics
Unless otherwise specified: TJ = 25°C, VIN = VO(NOM) + 1 V, IL = 1 mA, COUT = 1 μF, VON/OFF = 2 V.(1)
PARAMETER
TEST CONDITIONS
LP2980AI-XX (2)
MIN TYP MAX
LP2980I-XX (2)
MIN TYP MAX
UNIT
ΔVO
Output voltage
tolerance
Output voltage line
regulation
VIN – VO Dropout voltage(3)
IL = 1 mA
1 mA < IL < 50 mA
1 mA < IL < 50 mA
–40°C ≤ TJ ≤ 125°C
VO(NOM) + 1 V ≤ VIN ≤ 16 V
VO(NOM) + 1 V ≤ VIN ≤ 16 V
–40°C ≤ TJ ≤ 125°C
IL = 0
IL = 0, –40°C ≤ TJ ≤ 125°C
IL = 1 mA
IL = 1 mA, –40°C ≤ TJ ≤ 125°C
IL = 10 mA
IL = 10 mA, –40°C ≤ TJ ≤ 125°C
IL = 50 mA
IL = 50 mA, –40°C ≤ TJ ≤ 125°C
−0.5
−0.75
−2.5
0.007
0.007
1
1
7
7
40
40
120
120
0.5
0.75
2.5
0.014
0.032
3
5
10
15
60
90
150
225
−1
−1.5
−3.5
0.007
0.007
1
1
7
7
40
40
120
120
1
1.5 %VNOM
3.5
0.014
%/V
0.032
3
5
10
15
mV
60
90
150
225
(1) Minimum and maximum limits are ensured through test, design, or statistical correlation over the junction temperature (TJ) range of
–40°C to 125°C, unless otherwise stated. Typical values represent the most likely parametric norm at TA = 25°C, and are provided for
reference purposes only.
(2) Limits are 100% production tested at 25°C. Limits over the operating temperature range are ensured through correlation using Statistical
Quality Control (SQC) methods. The limits are used to calculate Average Outgoing Quality Level (AOQL).
(3) Dropout voltage is defined as the input to output differential at which the output voltage drops 100 mV below the value measured with a
1-V differential.
4
Submit Documentation Feedback
Copyright © 2000–2015, Texas Instruments Incorporated
Product Folder Links: LP2980-N