English
Language : 

CDCVF2310 Datasheet, PDF (4/23 Pages) Texas Instruments – 2.5-V TO 3.3-V HIGH-PERFORMANCE CLOCK BUFFER
CDCVF2310
SCAS666D – JUNE 2001 – REVISED OCTOBER 2015
www.ti.com
6.2 ESD Ratings
V(ESD)
Electrostatic
discharge
Human body model (HBM), per ANSI/ESDA/JEDEC JS-001 (1)
Charged-device model (CDM), per JEDEC specification JESD22-C101 (2)
VALUE
2000
1000
(1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(2) JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.
UNIT
V
6.3 Recommended Operating Conditions
See (1)
VDD Supply voltage
VIL
Low-level input voltage
VDD = 3 V to 3.6 V
VDD = 2.3 V to 2.7 V
VIH High-level input voltage
VDD = 3 V to 3.6 V
VDD = 2.3 V to 2.7 V
VI
Input voltage
IOH High-level output current
VDD = 3 V to 3.6 V
VDD = 2.3 V to 2.7 V
IOL
Low-level output current
VDD = 3 V to 3.6 V
VDD = 2.3 V to 2.7 V
TA
Operating free-air temperature
(1) Unused inputs must be held high or low to prevent them from floating.
MIN
NOM MAX UNIT
2.3
2.5
V
3.3
3.6
0.8
V
0.7
2
V
1.7
0
VDD V
12
mA
6
12
mA
6
–40
85 °C
6.4 Thermal Information
THERMAL METRIC (1)
CDCVF2310
PW (TSSOP)
UNIT
24 PINS
RθJA
RθJC(top)
RθJB
ψJT
ψJB
RθJC(bot)
Junction-to-ambient thermal resistance
Junction-to-case (top) thermal resistance
Junction-to-board thermal resistance
Junction-to-top characterization parameter
Junction-to-board characterization parameter
Junction-to-case (bottom) thermal resistance
91.7
°C/W
31.2
°C/W
46.4
°C/W
1.5
°C/W
45.8
°C/W
n/a
°C/W
(1) For more information about traditional and new thermal metrics, see the Semiconductor and IC Package Thermal Metrics application
report, SPRA953.
6.5 Electrical Characteristics
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
TEST CONDITIONS
VIK
Input voltage
II
Input current
IDD
Static device current
VDD = 3 V
VI = 0 V or VDD
CLK = 0 V or VDD ,
IO = 0 mA
II = –18 mA
-40°C to 85°C
≤105°C
CI
Input capacitance
CO
Output capacitance
VDD = 2.3 V to 3.6 V
VDD = 2.3 V to 3.6 V
VI = 0 V or VDD
VI = 0 V or VDD
(1) All typical values are at respective nominal VDD.
MIN TYP(1) MAX UNIT
–1.2 V
±5 μA
80 μA
100 μA
2.5
pF
2.8
pF
4
Submit Documentation Feedback
Product Folder Links: CDCVF2310
Copyright © 2001–2015, Texas Instruments Incorporated