CD74AC174_14 Datasheet, PDF (4/14 Pages) Texas Instruments – HEX D-TYPE FLIP-FLOP | |||
|
◁ |
CD74AC174
HEX D-TYPE FLIP-FLOP
WITH CLEAR
SCHS346 â APRIL 2003
timing requirements over recommended operating free-air temperature range, VCC = 3.3 V ± 0.3 V
(unless otherwise noted)
fclock Clock frequency
tw
Pulse duration
tsu
Setup time before CLKâ
th
Hold time, data after CLKâ
trec
Recovery time, before CLKâ
CLR low
CLK high or low
Data
CLRâ
â55°C to
125°C
MIN MAX
68
5.6
7.3
2
4.2
1.5
â40°C to
85°C
MIN MAX
77
4.9
6.4
2
3.7
1.5
UNIT
MHz
ns
ns
ns
ns
timing requirements over recommended operating free-air temperature range, VCC = 5 V ± 0.5 V
(unless otherwise noted)
fclock Clock frequency
tw
Pulse duration
tsu
Setup time before CLKâ
th
Hold time, data after CLKâ
trec
Recovery time, before CLKâ
CLR low
CLK high or low
Data
CLRâ
â55°C to
125°C
MIN MAX
95
4
5.2
2
3
1.5
â40°C to
85°C
MIN MAX
108
3.5
4.6
2
2.6
1.5
UNIT
MHz
ns
ns
ns
ns
switching characteristics over recommended operating free-air temperature range,
VCC = 1.5 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
â55°C to
125°C
MIN MAX
â40°C to 85°C
UNIT
MIN MAX UNIT
fmax
tPLH
tPHL
tPLH
tPHL
CLK
CLR
Any Q
Any Q
8
169
169
181
181
9
MHz
154
ns
154
165
ns
165
switching characteristics over recommended operating free-air temperature range,
VCC = 3.3 V ± 0.3 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
â55°C to
125°C
MIN MAX
â40°C to
85°C
MIN MAX
fmax
tPLH
tPHL
tPLH
tPHL
CLK
CLR
Any Q
Any Q
68
4.7 18.9
4.7 18.9
5.1 20.3
5.1 20.3
77
4.9 17.2
4.9 17.2
5.2 18.5
5.2 18.5
UNIT
MHz
ns
ns
4