English
Language : 

CD54AC08 Datasheet, PDF (4/14 Pages) Harris Corporation – Quad 2-Input AND Gate
CD54AC08, CD74AC08
QUADRUPLE 2-INPUT POSITIVE-AND GATES
SCHS307C – JANUARY 2001 – REVISED JUNE 2002
switching characteristics over recommended operating free-air temperature range,
VCC = 5 V ± 0.5 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
–40°C TO
85°C
MIN MAX
–55°C TO
125°C
MIN MAX
UNIT
tPLH
tPHL
A or B
2.2 7.9 2.2 8.7
Y
ns
2.2 7.9 2.2 8.7
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd Power dissipation capacitance
TYP UNIT
50 pF
4