English
Language : 

BQ20Z70_17 Datasheet, PDF (4/17 Pages) Texas Instruments – SBS 1.1-COMPLIANT GAS GAUGE ENABLED WITH IMPEDANCE TRACK TECHNOLOGY FOR USE WITH THE bq29330
bq20z70
Not Recommended For New Designs
SLUS686B – NOVEMBER 2005 – REVISED JULY 2007
ELECTRICAL CHARACTERISTICS
VCC = 2.4 V to 2.6 V, TA = -40°C - 85°C (unless otherwise noted)
PARAMETER
TEST CONDITIONS
VDD Supply voltage
IDD Operating mode current
VDDA and VDDD
No flash programming
bq20z70 + bq29330
I(SLP) Low-power storage mode current
Sleep mode
bq20z70 + bq29330
I(SLP) Shutdown Current
Shutdown Mode
bq20z70 + bq29330
VOL
Output voltage low CLKOUT, SAFE, SMBD, SMBC, SDATA,
SCLK
IOL = 7 mA
VOH Output high voltage CLKOUT, SAFE, SMBD,SMBC, SDATA, IOH = –0.5 mA
SCLK
VIL Input voltage low PRES, PFIN, SMBD, SMBC, SDATA, MRST
VIH Input voltage high PRES, PFIN, SMBD, SMBC, SDATA, MRST
CIN Input capacitance
V(AI1) Input voltage range TS1, TS2, VCELL+, VCELL-
V(AI2) Input voltage range SRP, SRN
Z(AI1) Input impedance TS1, TS2, VCELL+, VCELL -
0V–1V
Z(AI2) Input impedance SRP, SRN
0V–1V
(1) This value does not include the bq29330
www.ti.com
MIN TYP
2.4 2.5
400 (1)
475
8 (1)
48
0.1 (1)
0.2
MAX UNIT
2.6 V
μA
μA
μA
0.4 V
VCC – 0.5
V
2.0
– 0.2
– 0.2
8
2.5
0.8 V
V
5
pF
0.8 x VCC
V
0.2
MΩ
MΩ
POWER-ON RESET
VCC = 2.4 V to 2.6 V, TA = –40°C to 85°C (unless otherwise noted)
PARAMETER
VIT– Negative-going voltage input
VHYS Power-on reset hysteresis
TEST CONDITIONS
MIN TYP MAX UNIT
1.7 1.8 1.9 V
50 125 200 mV
1.81
1.8
1.79
1.78
1.77
1.76
-40 -20
0
20
40
60
80
TA - Free-Air Temperature - °C
4
Submit Documentation Feedback