74ACT16620 Datasheet, PDF (4/6 Pages) Texas Instruments – 16-BIT BUS TRANSCEIVERS WITH 3-STATE OUTPUTS | |||
|
◁ |
54ACT16620, 74ACT16620
16ÄBIT BUS TRANSCEIVERS
WITH 3ÄSTATE OUTPUTS
SCAS184A â JUNE 1990 â REVISED APRIL 1996
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
TA = 25°C
54ACT16620 74ACT16620
MIN TYP MAX MIN MAX MIN MAX
IOH = â50 µA
4.5 V 4.4
5.5 V 5.4
4.4
4.4
5.4
5.4
VOH
IOH = â24 mA
IOH = â75 mAâ
IOL = 50 µA
4.5 V 3.94
5.5 V 4.94
5.5 V
4.5 V
5.5 V
3.8
3.8
4.8
4.8
3.85
3.85
0.1
0.1
0.1
0.1
0.1
0.1
VOL
II
IOZâ¡
Control inputs
A or B ports
IOL = 24 mA
IOL = 75 mAâ
VI = VCC or GND
VO = VCC or GND
4.5 V
5.5 V
5.5 V
5.5 V
5.5 V
0.36
0.44
0.44
0.36
0.44
0.44
1.65
1.65
±0.1
±1
±1
±0.5
±5
±5
ICC
âICC§
VI = VCC or GND, IO = 0
One input at 3.4 V,
Other inputs at VCC or GND
5.5 V
5.5 V
8
80
80
0.9
1
1
Ci
Control inputs VI = VCC or GND
5V
4
Cio
A or B ports VO = VCC or GND
5V
15
â Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
â¡ For I/O ports, the parameter IOZ includes the input leakage current.
§ This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or VCC.
UNIT
V
V
µA
µA
µA
mA
pF
pF
switching characteristics over recommended operating free-air temperature range,
VCC = 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
TA = 25°C
54ACT16620 74ACT16620
MIN TYP MAX MIN MAX MIN MAX
tPLH
tPHL
tPZH
tPZL
tPHZ
tPLZ
tPZH
tPZL
tPHZ
tPLZ
A or B
OEBA
OEBA
OEAB
OEAB
B or A
A
A
B
B
2
5 7.7
2 8.5
2 8.5
4
7 9.3
4 10.5
4 10.5
2.2 5.5 8.3 2.2 9.1 2.2 9.1
2.8 6.4
10 2.8 10.9 2.8 10.9
6 8.8
11
6 11.9
6 11.9
5.1 7.9
10 5.1 10.6 5.1 10.6
3.6 6.2 7.9 3.6 8.9 3.6 8.9
4.4 7.1 9.4 4.4 10.5 4.4 10.5
5 7.8 10.1
5 10.8
5 10.8
4.1 6.7 9.1 4.1 9.6 4.1 9.6
UNIT
ns
ns
ns
ns
ns
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd Power dissipation capacitance per transceiver
Outputs enabled
Outputs disabled
TEST CONDITIONS
CL = 50 pF, f = 1 MHz
TYP UNIT
57
pF
10
PRODUCT PREVIEW information concerns products in the formative or
design phase of development. Characteristic data and other
specifications are design goals. Texas Instruments reserves the right to
change or discontinue these products without notice.
4
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265
⢠POST OFFICE BOX 1443 HOUSTON, TEXAS 77251â1443
|
▷ |